Evaluation of anesthesia residents using mannequin-based simulation: a multiinstitutional study.

نویسندگان

  • Howard A Schwid
  • G Alec Rooke
  • Jan Carline
  • Randolph H Steadman
  • W Bosseau Murray
  • Michael Olympio
  • Stephen Tarver
  • Karen Steckner
  • Susan Wetstone
چکیده

BACKGROUND Anesthesia simulators can generate reproducible, standardized clinical scenarios for instruction and evaluation purposes. Valid and reliable simulated scenarios and grading systems must be developed to use simulation for evaluation of anesthesia residents. METHODS After obtaining Human Subjects approval at each of the 10 participating institutions, 99 anesthesia residents consented to be videotaped during their management of four simulated scenarios on MedSim or METI mannequin-based anesthesia simulators. Using two different grading forms, two evaluators at each department independently reviewed the videotapes of the subjects from their institution to score the residents' performance. A third evaluator, at an outside institution, reviewed the videotape again. Statistical analysis was performed for construct- and criterion-related validity, internal consistency, interrater reliability, and intersimulator reliability. A single evaluator reviewed all videotapes a fourth time to determine the frequency of certain management errors. RESULTS Even advanced anesthesia residents nearing completion of their training made numerous management errors; however, construct-related validity of mannequin-based simulator assessment was supported by an overall improvement in simulator scores from CB and CA-1 to CA-2 and CA-3 levels of training. Subjects rated the simulator scenarios as realistic (3.47 out of possible 4), further supporting construct-related validity. Criterion-related validity was supported by moderate correlation of simulator scores with departmental faculty evaluations (0.37-0.41, P < 0.01), ABA written in-training scores (0.44-0.49, < 0.01), and departmental mock oral board scores (0.44-0.47, P < 0.01). Reliability of the simulator assessment was demonstrated by very good internal consistency (alpha = 0.71-0.76) and excellent interrater reliability (correlation = 0.94-0.96; P < 0.01; kappa = 0.81-0.90). There was no significant difference in METI versus MedSim scores for residents in the same year of training. CONCLUSIONS Numerous management errors were identified in this study of anesthesia residents from 10 institutions. Further attention to these problems may benefit residency training since advanced residents continued to make these errors. Evaluation of anesthesia residents using mannequin-based simulators shows promise, adding a new dimension to current assessment methods. Further improvements are necessary in the simulation scenarios and grading criteria before mannequin-based simulation is used for accreditation purposes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessing the performance and satisfaction of medical residents utilizing standardized patient versus mannequin-simulated training

BACKGROUND Conducting simulations of rapidly decompensating patients are a key part of internal medicine (IM) residency training. Traditionally, mannequins have been the simulation tool used in these scenarios. OBJECTIVE To compare IM residents' performance and assess realism in specific-simulated decompensating patient scenarios using standardized patients (SPs) as compared to mannequin. M...

متن کامل

A comparison of the training value of two types of anesthesia simulators: computer screen-based and mannequin-based simulators.

UNLABELLED In this study, we compared two different training simulators (the computer screen-based simulator versus the full-scale simulator) with respect to training effectiveness in anesthesia residents. Participants were evaluated in the management of a simulated preprogrammed scenario of anaphylactic shock using two variables: treatment score and diagnosis time. Our results showed that simu...

متن کامل

The Effect of Computer Simulation and Mannequin on Nursing Students’ Perception of Self-efficacy in Cardiopulmonary Resuscitation

Introduction: Resuscitation self-efficacy is defined as a judgment of perceived capability to organize and execute the process of care during cardiopulmonary resuscitation. It is believed to be an important factor in teaching vital nursing skills especially cardiopulmonary resuscitation. Therefore, this study aimed to investigate the impact of mannequin-based simulation and computer-based simul...

متن کامل

Simulation Training for Residents Focused on Mechanical Ventilation

INTRODUCTION Advances in knowledge regarding mechanical ventilation (MV), in particular lung-protective ventilation strategies, have been shown to reduce mortality. However, the translation of these advances in knowledge into better therapeutic performance in real-life clinical settings continues to lag. High-fidelity simulation with a mannequin allows students to interact in lifelike situation...

متن کامل

Simulator training enhances resident performance in transesophageal echocardiography.

BACKGROUND Standardized training via simulation as an educational adjunct may lead to a more rapid and complete skill achievement. The authors hypothesized that simulation training will also enhance performance in transesophageal echocardiography image acquisition among anesthesia residents. METHODS A total of 42 clinical anesthesia residents were randomized to one of two groups: a control gr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Anesthesiology

دوره 97 6  شماره 

صفحات  -

تاریخ انتشار 2002