Patient-specific modelling of head-up tilt.

نویسندگان

  • Nakeya D Williams
  • Øistein Wind-Willassen
  • Andrew A Wright
  • Jesper Mehlsen
  • Johnny T Ottesen
  • Mette S Olufsen
چکیده

Short-term cardiovascular responses to head-up tilt (HUT) involve complex cardiovascular regulation in order to maintain blood pressure at homoeostatic levels. This manuscript presents a patient-specific model that uses heart rate as an input to fit the dynamic changes in arterial blood pressure data during HUT. The model contains five compartments representing arteries and veins in the upper and lower body of the systemic circulation, as well as the left ventricle facilitating pumping of the heart. A physiologically based submodel describes gravitational pooling of the blood into the lower extremities during HUT, and a cardiovascular regulation model adjusts cardiac contractility and vascular resistance to the blood pressure changes. Nominal parameter values are computed from patient-specific data and literature estimates. The model is rendered patient specific via the use of parameter estimation techniques. This process involves sensitivity analysis, prediction of a subset of identifiable parameters, and non-linear optimization. The approach proposed here was applied to the analysis of aortic and carotid HUT data from five healthy young subjects. Results showed that it is possible to identify a subset of model parameters that can be estimated allowing the model to fit changes in arterial blood pressure observed at the level of the carotid bifurcation. Moreover, the model estimates physiologically reasonable values for arterial and venous blood pressures, blood volumes and cardiac output for which data are not available.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vestibular Function in Different Otoneurological Patients

Objectives The first objective was to evaluate feasibility of head tilt testing and the motorized head impulse test (mHIT) for the quantification of vestibular function and its possible change in different otoneurological patient groups. The second objective was to compare these objective findings with symptoms and other signs for these patients. Methods Head tilt was measured by using a commer...

متن کامل

Head-up-tilt testing in children: new perspectives using beat-to-beat blood-pressure monitoring

The head-up-tilt-test in pediatric patients for the evaluation of syncope shows a sensitivity of 35-85% and often requires pharmacological stimulation in order to improve its diagnostic value. We used a new device for beat-to-beat blood pressure monitoring combined with impedance cardiography in a 12-year-old girl during tilt testing. A seven seconds asystolia was provoked. The haemodynamic par...

متن کامل

Prediction of vasovagal syncope from heart rate and blood pressure trend and variability: experience in 1,155 patients.

BACKGROUND Vasovagal syncope (VVS) is a complex fainting disorder commonly triggered by orthostatic stress. OBJECTIVE We developed an algorithm for VVS prediction based on the joint assessment of RR interval (RR) and systolic blood pressure (SBP). METHODS Simultaneous analysis of RR and SBP trends during head-up tilt as well as their variability represented by low-frequency power (LFRR and ...

متن کامل

Effects of gravitational stresses on mitral valve prolapse. I. Changes in auscultatory findings produced by progressive passive head-up tilt.

The effects of passive head-up tilt on systolic time intervals were assessed in 18 patients with mitral valve prolapse. In addition to causing prolongation of the pre-ejection period and shortening of left ventricular ejection time, this circulatory stress led to progressive shortening of the Q to click interval. In 1 patient, a systolic click became audible which had not been heard in the supi...

متن کامل

Incidence of Venous Air Embolism during Myomectomy: The Effect of Patient Position

PURPOSE Venous air embolism (VAE) is characterized by the entrainment of air or exogenous gases from broken venous vasculature into the central venous system. No study exists regarding the effect of patient positioning on the incidence of VAE during abdominal myomectomy. The purpose of this study was to assess the incidence and grade of VAE during abdominal myomectomy in the supine position in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Mathematical medicine and biology : a journal of the IMA

دوره 31 4  شماره 

صفحات  -

تاریخ انتشار 2014