High-resolution far-infrared spectroscopy at NSLS beamline U12IR

نویسندگان

  • G. L. Carr
  • R. J. Smith
  • L. Mihaly
  • H. Zhang
  • D. H. Reitze
  • D. B. Tanner
چکیده

A Bruker model IFS 125HR Fourier transform interferometer has been installed and its performance tested using high-brightness, far-infrared synchrotron radiation. Results of absorption measurements for the rotational modes of water vapor demonstrate a nearly 10-fold improvement in signal-to-noise when compared with the instrument’s internal high-pressure Hg arc lamp source. 2008 Published by Elsevier B.V.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time-Resolved Infrared Spectroscopy on the U12IR Beamline at the NSLS

A facility for performing time-resolved infrared spectroscopy has been developed at the NSLS, primarily at beamline U12IR. The pulsed IR light from the synchrotron is used to perform pump-probe spectroscopy. We present here a description of the facility and results for the relaxation of photoexcitations in both a semiconductor and superconductor.

متن کامل

Investigation of Coherent Emission from the NSLS VUV Ring

Coherent synchrotron radiation from the NSLS VUV ring has been detected and partially characterized. The observations have been performed at the new far infrared beamline U12IR. The coherent radiation is peaked near a wavelength of 7mm and occurs in short duration bursts. The bursts occur only when the electron beam current (I) exceeds a threshold value (Ith), which itself varies with ring oper...

متن کامل

Performance of new infrared beamline U12IR at the National Synchrotron Light Source

The instrumentation and performance of the new infrared beamline U12IR at the National Synchrotron Light Source of Brookhaven National Laboratory is described. This beamline utilizes infrared synchrotron radiation from a bending magnet. A combination of beamline design features and spectroscopic instrumentation allows the facility to reach the extremely low frequency limit of ;2 cm ~i.e., 60 GH...

متن کامل

The revitalized NSLS VUV ring

A status report on the revitalization of the NSLS VUV ring will be presented, concentrating on three areas: 1) the four infrared ports (U2A/B, U4IR, U10A/B, and U12IR), 2) conversion of out-of-date toroidal grating monochromators to spherical grating type (U4A, U7A, and U12A), and 3) new insertion device beamlines (U5UA and U13UB). All of these beamlines were designed (new ones) or upgraded (ol...

متن کامل

Correlated single-crystal electronic absorption spectroscopy and X-ray crystallography at NSLS beamline X26-C

The research philosophy and new capabilities installed at NSLS beamline X26-C to support electronic absorption and Raman spectroscopies coupled with X-ray diffraction are reviewed. This beamline is dedicated full time to multidisciplinary studies with goals that include revealing the relationship between the electronic and atomic structures in macromolecules. The beamline instrumentation has be...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008