Intimal injury of ultrasonically skeletonized internal thoracic artery by a vessel clamp: morphological analysis.

نویسندگان

  • Masaru Yoshikai
  • Tsuyoshi Itoh
  • Keiji Kamohara
  • Junji Yunoki
  • Hideyuki Fumoto
چکیده

The skeletonized internal thoracic artery (ITA) has several advantages over a pedicled one in coronary artery bypass grafting. A skeletonized ITA, which lacks surrounding tissue, thus seems more susceptible to the mechanical force exerted by a vessel clamp than the pedicled ITA. The purpose of this study was to assess the detrimental effect of vessel clamps on the intimal integrity of the ultrasonically skeletonized ITA. We skeletonized twelve ITAs with an ultrasonic scalpel in patients who underwent coronary artery bypass grafting, and thereafter two types of clamp, namely a metal clamp and a fibrous jaw clamp, were applied to the terminal portion of the ITA for 30 min. The intimal integrity of the ITAs was morphologically assessed using scanning electron microscopy. A metal clamp can cause serious intimal injury which disrupts the internal elastic lamina, and thus should be avoided for the temporary clamping of the skeletonized ITA. A fibrous jay clamp, however, hardly ever causes intimal injury, and its clinical use for the temporary clamping of the ultrasonically skeletonized ITA is therefore recommended. Vessel clamps can cause intimal injury of the ultrasonically skeletonized ITA, and the degree of the injury depends on the type of the clamp used.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

eComment: Sternal microcirculation following pedicled or skeletonized internal thoracic artery harvesting.

Technical aspects of composite arterial grafting with double skeleton-ized internal thoracic arteries. Bilateral skeleton-ised internal thoracic artery graftings in off-pump coronary artery bypass: early result of Y versus in situ grafts. results of coronary grafting using ultrasonically skeletonized internal thoracic arteries. We read with great interest the recent review from Dr. Ali and cowo...

متن کامل

Intraoperative and laboratory evaluation of skeletonized versus pedicled internal thoracic artery.

BACKGROUND The skeletonization of internal thoracic artery is postulated to improve graft length, early blood flow, sternal blood supply, and postoperative respiratory function. Concern exists that skeletonization may injure internal thoracic artery, precluding good results of surgery. Reports on endothelial function of skeletonized internal thoracic artery are lacking. METHODS A prospective ...

متن کامل

Early results of thoracoscopic internal mammary artery harvest using an ultrasonic scalpel.

OBJECTIVE We developed a thoracoscopic internal mammary artery harvest technique using an ultrasonic scalpel, the Harmonic Scalpel (Ethicon Endo-Surgery, Cincinnati, OH). This is the first report of 9 month follow-up using this technique. METHODS The Harmonic Scalpel is activated ultrasonically by vibrating at 55000 Hz. Compared with electrocautery, lower heat (<100 degrees C) and less smoke ...

متن کامل

Midterm results for use of the skeletonized gastroepiploic artery graft in coronary artery bypass.

BACKGROUND To improve the long-term results of coronary artery bypass grafting (CABG), several arterial conduits have been used, including the skeletonized right gastroepiploic artery (GEA) graft. METHODS AND RESULTS The skeletonized GEA graft was used for CABG in 223 patients over a 6-year period (208 males, 15 females, mean age 64 years). 1-, 2- and 3-vessel and left main trunk disease was ...

متن کامل

Flow capacity of skeletonized versus pedicled internal thoracic artery in coronary artery bypass graft surgery: systematic review, meta-analysis and meta-regression.

Many surgeons are concerned about the flow capacity of a skeletonized internal thoracic artery (ITA) in comparison with a pedicled ITA used during coronary artery bypass graft (CABG). This work aims to summarize the evidence comparing the flow capacity of a skeletonized versus pedicled ITA during CABG. We performed systematic review and meta-analysis according to the PRISMA statement based on a...