An improvement on the criterion of the state of the art to estimate the maximal allowable imprecision.
نویسندگان
چکیده
One criterion recommended (1,2) for establishing the maximal allowable imprecision is derived from the biological variability data. According to this criterion, the metrological coefficient of variation must be equal to or less than one-half of the within-subject biological coefficient of variation. When information about biological variability is not available, or when current procedures give better results for imprecision than the goals set with this criterion, the so-called "state of the art" criterion is generally used. According to this criterion, the maximal allowable imprecision for physiological concentrations must be less than the 0.20 fractile of the between-run imprecision (CV) of the laboratories in an external quality assessment scheme.
منابع مشابه
FUZZY TRAIN ENERGY CONSUMPTION MINIMIZATION MODEL AND ALGORITHM
Train energy saving problem investigates how to control train's velocity such that the quantity of energy consumption is minimized and some system constraints are satis ed. On the assumption that the train's weights on different links are estimated by fuzzy variables when making the train scheduling strategy, we study the fuzzy train energy saving problem. First, we propose a fuzzy energy ...
متن کاملAn Improved Motion Vector Estimation Approach for Video Error Concealment Based on the Video Scene Analysis
In order to enhance the accuracy of the motion vector (MV) estimation and also reduce the error propagation issue during the estimation, in this paper, a new adaptive error concealment (EC) approach is proposed based on the information extracted from the video scene. In this regard, the motion information of the video scene around the degraded MB is first analyzed to estimate the motion type of...
متن کاملA Novel Method for Automated Estimation of Effective Parameters of Complex Auditory Brainstem Response: Adaptive Processing based on Correntropy Concept
Objectives: Automated Auditory Brainstem Responses (ABR) peak detection is a novel technique to facilitate the measurement of neural synchrony along the auditory pathway through the brainstem. Analyzing the location of the peaks in these signals and the time interval between them may be utilized either for analyzing the hearing process or detecting peripheral and central lesions in the human he...
متن کاملA Novel NeighShrink Correction Algorithm in Image Denoising
Image denoising as a pre-processing stage is a used to preserve details, edges and global contrast without blurring the corrupted image. Among state-of-the-art algorithms, block shrinkage denoising is an effective and compatible method to suppress additive white Gaussian noise (AWGN). Traditional NeighShrink algorithm can remove the Gaussian noise significantly, but loses the edge information i...
متن کاملThe Finite Element Transient Structure Analysis of the Startup of the Sugarcane Harvester Transfer Case
The broken bearings and great noise and vibration often occurs with the small sugarcane harvester transfer case when it starts up working. To analyze the startup status of the transfer case conveniently and quickly, the finite element transient structure analysis is carried out. with virtual prototype technology to simulate the transfer case's startup dynamic process and measure the instantaneo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies
دوره 34 5 شماره
صفحات -
تاریخ انتشار 1996