Inconsistencies between navigation data and radiographs in total knee arthroplasty are system-dependent and affect coronal alignment.
نویسندگان
چکیده
BACKGROUND Few studies have compared the effect of different computer navigation systems on postoperative alignment in patients who have had total knee arthroplasty (TKA). We examined 2 computed tomography (CT)-free computer navigation systems by comparing the accuracy of intraoperative measurements to postoperative alignment. METHODS Patients underwent unilateral TKA performed by a single surgeon using 1 of 2 CT-free navigation systems. We compared final intraoperative tibial and femoral coronal angles and mechanical axis with the same angles measured on standing postoperative radiographs. RESULTS Groups of 31 and 50 patients underwent TKA with the 2 systems, respectively. We noted a significant difference in the coronal tibial implant angle (1.29º ± 1.35º) and in the mechanical axis (1.59º ± 2.36º) for one navigation system (both p < 0.001), while only the coronal tibial implant angle showed a significant difference (1.17º ± 1.65º, p < 0.001) for the second system. The number of radiographic outliers also significantly differed. A significantly higher proportion (32%; p < 0.01) of patients in the second cohort exhibited unacceptable malalignment compared with the first cohort (24%). CONCLUSION Navigation systems for TKA continue to increase in sophistication and popularity. Owing to the significant difference in the proportion of alignment outliers in the 2 navigation systems tested in this study, orthopedic surgeons should not consider all TKA navigation systems equivalent. Additional investigations are needed to compare the accuracy of a variety of CT-free and CT-based navigation systems and to confirm our finding that accuracy is system-dependent.
منابع مشابه
The Effect of Sagittal Knee Deformity on Preoperative Measurement of Coronal Mechanical Alignment during Total Knee Arthroplasty
Purpose The purpose of this prospective study was to determine correlation between coronal mechanical alignment measured on preoperative standing full-length radiographs and navigation during total knee arthroplasty (TKA) in the presence of an associated sagittal deformity (hyperextension and flexion deformity). Materials and Methods Coronal mechanical alignment measured on preoperative, stan...
متن کاملRadiographic results of an accelerometer-based, handheld surgical navigation system for the tibial resection in total knee arthroplasty.
In total knee arthroplasty (TKA), intramedullary and extramedullary tibial alignment guides are not proven to be highly accurate in obtaining alignment perpendicular to the mechanical axis in the coronal plane. The objective of this study was to determine the accuracy of an accelerometer-based, handheld surgical navigation system in obtaining a postoperative tibial component alignment within 2°...
متن کاملUsing Accelerometer-Based Portable Navigation to Perform Accurate Total Knee Arthroplasty Bone Resection in Asian Patients.
Implant alignment is an important factor affecting clinical results associated with total knee arthroplasty (TKA). No report exists showing the utility of an accelerometer-based portable navigation system among patients with marked femoral bowing. The aim of this study was to evaluate the accuracy of a portable navigation system for implant alignment in Asian patients with marked femoral bowing...
متن کاملThe Effect of Sagittal Femoral Bowing on the Femoral Component Position in Total Knee Arthroplasty
Background: In the current study, we investigated that how sagittal femoral bowing can affect the sagittal alignment ofthe femoral component in total knee arthroplasty (TKA).Methods: There were 25 patients underwent TKA. Long leg radiography in lateral view was performed. The sagittalfemoral bowing (SFB) and component alignment in relation to the sagittal mechanical axis and distal anterior cor...
متن کاملComparison of an Accelerometer-Based Portable Navigation System, Patient-Specific Instrumentation, and Conventional Instrumentation for Femoral Alignment in Total Knee Arthroplasty
Purpose The KneeAlign2 (KA2, OrthoAlign Inc.) accelerometer-based portable navigation system and patient-specific instrumentation (PSI; Signature, ZimmerBiomet) are widely used for ideal femoral component alignment in total knee arthroplasty (TKA). However, there has been no comparative study of the KA2 system, PSI, and conventional intramedullary instrumentation (CON). The purpose of this stud...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Canadian journal of surgery. Journal canadien de chirurgie
دوره 57 5 شماره
صفحات -
تاریخ انتشار 2014