Late-stage non-anastomotic rupture of axillo-bifemoral bypass graft.
نویسندگان
چکیده
An 82-year-old woman, who underwent axillo-bifemoral bypass for infrarenal aortic occlusion and peripheral arterial occlusive disease 9 years before, was admitted to our hospital for swelling in the left subclavicular region. Ultrasound examination revealed a leak in the wall of the bypass graft with the formation of a false aneurysm. No signs of infection, either locally or systemically, were observed. Resection of the aneurismal segment with interposition using a Dacron graft was performed. Macroscopic findings during surgery confirmed an intact anastomotic region of the left axillary artery and Dacron graft. Two possible mechanisms for the formation of this false aneurysm, either cumulative stress on the graft over the years or Dacron graft biodegradation, were hypothesized.
منابع مشابه
Intrinsic structural failure of polyester (Dacron) vascular grafts. A general review.
Intrinsic structural failure of Dacron prostheses is a late exceptional complication, resulting from a loss of structural integrity of the graft. The authors report six cases of non-anastomotic false aneurysms in the mid-portion of a vascular Dacron graft, observed at a mean of 12 years after insertion. It concerns four femoro-popliteal bypass grafts, one cross-over graft and a branch of a bifu...
متن کاملDirect vancomycin irrigation as treatment for resistant aortic bed infection
Introduction: A case report of direct vancomycin irrigation as management of retroperitoneal abscess following removal of infected aortic graft. Case Report: A 63-yearold man presented nine years following aortic aneurysm repair with recurrence of aneurysm. At re-operation, aortic graft infection was diagnosed and managed with graft excision, debridement, axillo-bifemoral bypass and prolonged s...
متن کاملCommon iliac aneurysm rupture after previous aortic aneurysm resection.
INTRODUCTION Ruptured common iliac aneurysms present with diagnostic and therapeutic challenges. This case describes the successful outcome in a patient with complex vascular surgical history. CASE PRESENTATION An elderly patient presented with abdominal pain confirmed by CT as leaking iliac aneurysm. He had previously undergone an aorto-bifemoral bypass graft for ruptured abdominal aortic an...
متن کاملLate rupture of knitted Dacron graft.
An 87-year-old man underwent aorto-bifemoral bypass using a bifurcated Bionit II knitted Dacron graft for high aortic occlusion in 1987 at another hospital. In November, 2004, he was admitted to our institution because of difficulty in walking due to swelling and tenderness in the right groin. Computed tomography (CT) scan indicated bilateral aneurysms of the grafts in the groins. The size of t...
متن کاملNon-Anastomotic Rupture of a Woven Dacron Graft in the Descending Thoracic Aorta Treated with Endovascular Stent Grafting
The intrinsic structural failure of a Dacron graft resulting from the loss of structural integrity of the graft fabric can cause late graft complications. Late non-anastomotic rupture has traditionally been treated surgically via open thoracotomy. We report a case of the successful use of thoracic endovascular repair to treat a Dacron graft rupture in the descending aorta. The rupture occurred ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia
دوره 18 5 شماره
صفحات -
تاریخ انتشار 2012