Comparison of the Cleaning Efficacy of the Fkg Race System and Hand Instrument in Molar Root Canal

نویسندگان

  • Carla Renata SIPERT
  • Renata Pardini HUSSNE
  • Celso Kenji NISHIYAMA
چکیده

INTRODUCTION AND OBJECTIVE The aim of this study was to evaluate the ability of root canal cleaning of the RaCe rotary instrumentation system (FKG Dentaire - La-Cheaux-de Fonds - Switzerland), compared to manual filing with Stainless Steel K-files (Maillefer Instruments - Ballaigues - Switzerland). MATERIAL AND METHOD Twenty extracted human teeth (maxillary molars) were selected and their pulp tissue was removed after coronal access. The root canals were filled with a dye (India ink) and allowed to dry for 48 hours, followed by establishment of the working length of the mesiobuccal root; then, half of the specimens were instrumented by the modified Oregon technique and the other half were instrumented by crown-down sequence of the RaCe system. After preparation, the teeth were longitudinally sectioned and evaluated according to the amount of remaining dye. RESULTS Data obtained were registered as numerical scores, and the arithmetic means were compared between groups using the Mann Whitney test. Both techniques were unable to completely clean the interior of the root canals, with a better performance of the manual technique only at the middle third. CONCLUSION It could be concluded that the RaCe system was able to provide satisfactory cleaning, similar to that obtained by the manual instrumentation technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Comparison of two systems of Joy Taper and Bio Race in Transportation and preservation oc central position of curved canals (An invitro Study)

Objective :One of the important measure of proper root canal preparation is Maintaining the original position of the root canal.so ;instrument that result in Minimal change of canal position ,result in better cleaning and shaping . the aim of This study was to comparison of effect of Joy Taper and Bio Race on maintaining of Canal centering ability and transportation by CBCT in mesio buccal cana...

متن کامل

مقایسه آماده‌سازی کانال ریشه با استفاده از فایل‌های نیکل تیتانیومی دستی و روتاری Race

Introduction: Successful treatment of root depends on complete elimination of debris and bacteria’s from root canal system and appropriate shaping of canal in obturation canal preparation is the most difficult and time consuming stage during root canal treatment. This stage especially in curved and narrow canals always causes some problems for students, general dentist and specialist. Following...

متن کامل

Comparison of the maintenance of root canal anatomy in severely curved resin blocks using RaCe and Flexmaster rotary systems

Comparison of the maintenance of root canal anatomy in severely curved resin blocks using RaCe and Flexmaster rotary systems Dr. S. Khedmat* - Dr. M. Vahdatifar** *- Associate Professor of Endodontics Dept. - Faculty of Dentistry – Tehran University of Medical Sciences. **- Endodontist. Background and Aim: Various rotary systems are available on the market, therefore selection of a proper instr...

متن کامل

Comparison of canal transportation after preparation by 3 different rotary systems

Comparison of canal transportation after preparation by 3 different rotary systems Dr. Javidi, M.* - Dr. Zarei, M.* - Dr. Vatanpour, M.** *Assistant Professor of Endodontics Dept., Faculty of Dentistry, Mashhad University of Medical Sciences. **Assistant Professor of Endodontics Dept., Faculty of Dentistry, Tehran Azad University. Abstract Background & Aim: Cleaning and shaping has been recogni...

متن کامل

Research Paper: Comparison efficacy of calcium hydroxide removal by Revo-s, Protaper Rotary file from root canal

Abstract Introduction: The aim of this study was to evaluate the efficacy of two rotary instrument systems (ProTaper and Revo-s File) in removing calcium hydroxide residues from root canal walls Materials and Methods:Thirty human  maxillary incisors were instrumented with the ProTaper System up to the F2 instrument, irrigated with 2.5% NaOCl,and filled with a calcium hydroxide intracanal dr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2006