JOMI on CD-ROM (1997 © Quintessence Pub. Co.), 1997 Vol. 12, No. 4 (495 - 503): Ten-Year Results for Brånemark Implants Immedia

نویسنده

  • Paul A. Schnitman
چکیده

This investigation was initiated to develop a method to provide patients with a fixed provisional prosthesis placed at the time of implant placement. Sixty-three standard 3.75-mm Nobel Biocare implants of varying lengths were placed into mandibular sites in 10 patients and followed for up to 10 years. Twenty-eight implants were immediately loaded at implant placement, providing support for fixed provisional prostheses, while 35 adjacent implants were allowed to heal submerged and stress-free. Following a 3-month healing period, the submerged implants were exposed and definitive reconstruction was accomplished. All 10 prostheses supported by 28 implants placed into immediate function at the time of implant placement were successful during the 3-month healing period. Of these 28 implants placed into immediate function, 4 ultimately failed. Of the 35 submerged implants, all are osseointegrated and in function to date. Life-table analysis demonstrates an overall 10-year survival rate of 93.4% for all implants. The 10-year life-table analysis of survival is 84.7% for immediately loaded implants and 100% for submerged implants. Statistical analysis of the submerged versus immediately loaded implants demonstrates failure rates for immediately loaded implants to be significantly higher (P = .022 by the log rank test). These data demonstrate that although mandibular implants can be successfully placed into immediate function in the short term to support fixed provisional prostheses, long-term prognosis is guarded for those implants placed into immediate function distal to the incisor region. (INT J ORAL MAXILLOFAC IMPLANTS 1997;12:495–503)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

JOMI on CD-ROM (1997 © Quintessence Pub. Co.), 1997 Vol. 12, No. 6 (814 - 819): Placement of Screw-Type Implants in the Pterygo

A surgical technique for the placement of titanium screw-type implants (Brånemark system) in the pterygomaxillary-pyramidal region is presented. The correct direction, location, and length of the implant is decided during surgery. Cylindric osteotomes are used as bone-site formers, thus minimizing the use of drills in bone preparation. This not only conserves bone, but greatly reduces the poten...

متن کامل

JOMI on CD-ROM (1997 © Quintessence Pub. Co.), 1997 Vol. 12, No. 4 (558 - 561): Hemorrhage in the Floor of the Mouth During Imp

This report describes a life-threatening hemorrhage in the floor of a patient’s mouth during routine implant placement in the anterior mandible. Airway obstruction caused by hematoma development resulted in acute nasotracheal intubation and subsequent surgical intervention. Surgical, radiographic, and anatomic considerations to prevent severe bleeding are discussed. An extraoral submental appro...

متن کامل

JOMI on CD-ROM (1997 © Quintessence Pub. Co.), 1994 Vol. 9, No. 4 (455 - 460): A Comparison of the Accuracy of Periapical, Panor

A customized acrylic-resin template with gutta percha markers was fabricated for a human cadaver mandible. Twelve measurements were made between gutta percha markers and between the markers and known mandibular anatomic locations. Periapical, panoramic, and computerized tomographic radiographs were taken of the mandible and stent. Similar readings were recorded from the radiographs. The average...

متن کامل

JOMI on CD-ROM (1997 © Quintessence Pub. Co.), 1997 Vol. 12, No. 3 (319 - 324): Immediate Loading of Threaded Implants at Stage

Immediate loading of threaded implants with a fixed provisional restoration at stage 1 surgery was evaluated in 10 consecutive patients. The patients selected had to be completely edentulous and have adequate bone for a minimum of 10-mm-long implants. A minimum of 10 implants were placed in each patient’s arch. A minimum of five implants were submerged initially for medicolegal reasons and allo...

متن کامل

JOMI on CD-ROM (1997 © Quintessence Pub. Co.), 1996 Vol. 11, No. 3 (331 - 339): Determination of Cantilever Length Anterior-Pos

The maximum cantilever length-anterior-posterior spread (CL-AP) ratio is often used as an indication of the ability to cantilever in completely implant-supported prostheses. The CL-AP ratios were determined assuming that failure occurs when the prosthesis retaining screw-prosthesis joint was compromised by either compressive (exceeding the pretorque value) or tensile (opening of the joint via p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011