Bioreactance is a reliable method for estimating cardiac output at rest and during exercise.
نویسندگان
چکیده
BACKGROUND Bioreactance is a novel noninvasive method for cardiac output measurement that involves analysis of blood flow-dependent changes in phase shifts of electrical currents applied across the thorax. The present study evaluated the test-retest reliability of bioreactance for assessing haemodynamic variables at rest and during exercise. METHODS 22 healthy subjects (26 (4) yrs) performed an incremental cycle ergometer exercise protocol relative to their individual power output at maximal O2 consumption (Wmax) on two separate occasions (trials 1 and 2). Participants cycled for five 3 min stages at 20, 40, 60, 80 and 90% Wmax. Haemodynamic and cardiorespiratory variables were assessed at rest and continuously during the exercise protocol. RESULTS Cardiac output was not significantly different between trials at rest (P=0.948), or between trials at any stage of the exercise protocol (all P>0.30). There was a strong relationship between cardiac output estimates between the trials (ICC=0.95, P<0.001) and oxygen consumption (ICC=0.99, P<0.001). Stroke volume was also not significantly different between trials at rest (P=0.989) or during exercise (all P>0.15), and strong relationships between trials were found (ICC=0.83, P<0.001). CONCLUSIONS The bioreactance method demonstrates good test-retest reliability for estimating cardiac output at rest and during different stages of graded exercise testing including maximal exertion.
منابع مشابه
Quantification of the impaired cardiac output response to exercise in heart failure: application of a non-invasive device.
An impaired cardiac output (CO) response to exercise is a hallmark of chronic heart failure (CHF), and the degree to which CO is impaired is related to the severity of CHF and prognosis. However, practical methods for obtaining cardiac output during exercise are lacking, and what constitutes and impaired response is unclear. Forty six CHF patients and 13 normal subjects underwent cardiopulmonar...
متن کاملA multicenter study of noninvasive cardiac output by bioreactance during symptom-limited exercise.
BACKGROUND Hemodynamic responses to exercise were assessed in patients with varying degrees of chronic heart failure (CHF) to determine the feasibility of using bioreactance during exercise testing in multicenter studies of CHF. METHODS AND RESULTS A total of 210 symptomatic CHF patients and 22 subjects without heart failure were subjected to symptom-limited exercise testing on a bicycle (105...
متن کاملBioreactance Is Not Interchangeable with Thermodilution for Measuring Cardiac Output during Adult Liver Transplantation
BACKGROUND Thermodilution technique using a pulmonary artery catheter is widely used for the assessment of cardiac output (CO) in patients undergoing liver transplantation. However, the unclearness of the risk-benefit ratio of this method has led to an interest in less invasive modalities. Thus, we evaluated whether noninvasive bioreactance CO monitoring is interchangeable with thermodilution t...
متن کاملCardiac output measured by transthoracic impedance cardiography at rest, during exercise and at various lung volumes.
1. Cardiac output measured by transthoracic impedance cardiography has been compared with simultaneous measurements made by the indirect Fick CO2 rebreathing method in nine adults and 14 children. All were healthy normal volunteers. Sixty-six comparisons were made at rest and during steady exercise at work loads up to 100 W. 2. Impedance measurements of cardiac output were consistently higher t...
متن کاملBioreactance is not reliable for estimating cardiac output and the effects of passive leg raising in critically ill patients.
BACKGROUND Bioreactance estimates cardiac output in a non-invasive way. We evaluated the ability of a bioreactance device (NICOM®) to estimate cardiac index (CI) and to track relative changes induced by volume expansion. METHODS In 48 critically ill patients, we measured CI estimated by the NICOM® device (CINicom) and by transpulmonary thermodilution (CItd, PiCCO2™ device) before and after a ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British journal of anaesthesia
دوره 115 3 شماره
صفحات -
تاریخ انتشار 2015