Simulation studies for device evaluation.

نویسنده

  • Robert L Chatburn
چکیده

ever, this rate reached 52% (16/31) in those who were comatose during the first 24 h (defined as Glasgow coma scale 8). It has already been found that NIV can be successful in subjects with hypercapnic coma, and NIV failure rates of only 20% have been reported.3 It is important to note that patients who succeed with NIV have a faster improvement of consciousness compared with those who need intubation.3 Dr Briones Claudett emphasizes that subjects with altered consciousness may require higher levels of pressure support than those with normal consciousness. To support this, BrionesClaudett et al4 recently foundafaster recovery from hypercapnic encephalopathy using ventilatory mode with average volume-assured pressure support compared withpressure supportventilationduringNIV due to higher levels of ventilatory assistance and larger tidal volumes (VT). In our cohort, of the 31 subjects who developed hypercapnic coma, 15 were comatose upon admission, and 16 developed coma during the first 24 h while receiving NIV.1 The rate of intubation was only 20% (3/15) in subjects who were comatose at admission, in line with the results found by Díaz et al.3 By contrast, the rate of intubation was 81% (13/16) in those who developed delayed coma during NIV (P .001). Subjects with hypercapnic coma upon admission had similar VT values compared with other subjects (459 175 vs 469 142 mL, P .82). However, they received higher pressure support levels (11.9 2.7 vs 9.1 2.5 cm H2O, P .008), meaning that the level of ventilatory assistance had been correctly adjusted according to our protocol that aims to target predetermined VT. As we used exclusively ICU ventilators, inspiratory positive airway pressure, including pressure support and PEEP, reached 16.5 2.8 cm H2O in subjects who were comatose at admission, a value close to that reported in the abovementioned studies.3,4 We agree that adjustment of an adequate pressure support level is the key setting to reverse hypercapnic coma, and we believe that our good results are due in part to our protocol of adjusting the pressure support level to target a minimal VT, as would average volume-assured pressure support. Altered consciousness at admission does not seem to increase the risk of NIV failure. By contrast, almost all subjects who developed delayed coma needed intubation, whereas their VT values and their pressure support levels adjusted at admission were similar to those of other patients (417 142 vs 471 142 mL, P .27; 9.1 7.4 vs 9.2 2.6 cm H2O, P .88). Therefore, NIV failure was probably due to a patient’s worsening and/or failure of this treatment and not to inadequate adjustment of ventilatory settings.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation and Simulation of the Effects of Dispersion and Transmittance angles on the Solar Cells Quantum Efficiency

In this paper the effects of transmittance, dispersion angle and diffusion length on the quantum efficiency of solar cells (QESC) have been simulated and investigated. Optical path technic is used for simulation. The results show that base thickness, diffusion length, dispersion angle, number of optical confinement path and transmission angles have an extremely effects on the QESC. Simulation r...

متن کامل

Application of perfect mixing model for simulation of vertical roller mills

Vertical roller mills (VRMs) are well-established grinding equipment for various tasks in the coal and cement industry. There are few studies on simulation of VRMs. In this research work, application of perfect mixing model for simulation of a VRM in a cement grinding plant was investigated. Two sampling surveys were carried out on the VRM circuit. The samples and data from the first survey wer...

متن کامل

Simulation of environmental dose distribution of nuclear gauge device MC-1DR by MCNPX code

In this study, distribution of dose rate around the nuclear gauge device MC-1DR which located in shahrekord university was simulated by MCNPX code and was compared whit the measured values. Due to the asymmetry of device and neutron and gamma source positions, the dose rates were determined at a distance of 5, 30 and 100 cm in different directions. Base on the complex geometry of the inside of ...

متن کامل

Performance evaluation of Carbon nanotube junctionless tunneling field effect transistor (CNT-JLTFET) under torsional strain: A quantum simulation study

In this paper, the performance of a CNT-JLTFET under different values of torsional strains of 0, 3, and 5 degrees has been investigated. Simulation has been carried out using non-equilibrium Green’s function (NEGF) formalism in the mode-space approach and in the ballistic limit. The simulation results indicate that, under torsional strain, an increase occurs in the energy band-gap, and thus the...

متن کامل

A simulation study on the performance of various label-free electronic biosensors

The efficient detection of charged biomolecules by biosensor with appropriate semiconducting nanomaterials and with optimum device geometry has caught tremendous research interest in the present decade. Here, the performance of various label-free electronic biosensors to detect bio-molecules is investigated by simulation technique. Silicon nanowire sensor, nanosphere sensor and double gate fiel...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Respiratory care

دوره 59 4  شماره 

صفحات  -

تاریخ انتشار 2014