Simultaneous measurement of electron and ion temperatures with helium-like argon spectrum
نویسندگان
چکیده
The helium-like argon spectrum is measured for the plasma in the Large Helical Device (LHD). The electron temperature Te derived from the intensity ratio of the resonance line (1s2 S0 – 1s2p P1) to a dielectronic satellite line (1s22p P1/2 – 1s2p2 D3/2) is consistent with the central Te measured with the Thomson scattering method when the electron density ne has a peaked profile. The ion temperature Ti is simultaneously determined from the Doppler broadening width of the resonance line and the establishment of thermal equipartition between electrons and ions, i.e., Ti = Te, due to the increase of ne is experimentally confirmed.
منابع مشابه
Damage studies on irradiated tungsten by helium and argon ions in a plasma focus device
Damage of tungsten due to helium and argon ions of a PF device was studied. Tungsten samples were irradiated by 20 shots of the plasma focus device with argon and helium as working gases, separately. The tungsten surface was analyzed by SEM, before and after irradiation. SEM revealed dense blisters with diameters of a few hundred nanometers, on the samples which were irradiated by helium ions, ...
متن کاملNumerical Study of Radiation Emission from the Argon Plasma Focus
Ion populations and emitted spectrum of argon plasma have been calculated using the POPULATE and SPECTRA codes of the RATION suite at different conditions (electron temperatures, electron densities, ion densities, plasma size) for LTE and NLTE models. Expected argon plasma spectra at certain electron temperature range have been plotted. The suitable electron temperatures ranges for argon plasma...
متن کاملContinuous wave cavity ring down spectroscopy measurements of velocity distribution functions of argon ions in a helicon plasma.
We report continuous wave cavity ring down spectroscopy (CW-CRDS) measurements of ion velocity distribution functions (VDFs) in low pressure argon helicon plasma (magnetic field strength of 600 G, T(e) ≈ 4 eV and n ≈ 5 × 10(11) cm(-3)). Laser induced fluorescence (LIF) is routinely used to measure VDFs of argon ions, argon neutrals, helium neutrals, and xenon ions in helicon sources. Here, we d...
متن کاملElectron heating and density production in microwave-assisted helicon plasmas
Microwaves are injected into argon and helium helicon plasmas at 6 to 20 mTorr neutral pressure, 1.2 kW pulsed microwave power, up to 500 W continuous RF power, and up to 1 kG magnetic fields, with the objective of heating the tail of the electron energy distribution function (EEDF) and populating ion metastable states. Langmuir probes are used to measure the EEDF and optical emission spectrosc...
متن کاملA continuous flow mass spectrometry technique of argon isotope measurement for K/Ar geochronology.
A new method for the measurement of argon isotope composition in a continuous flow of helium for potassium/argon geochronology is described. Extraction of argon from geological samples in multiple-sample holders was carried out in a chamber by heating with a continuous Nd-YAG laser. The extracted and pre-concentrated argon is passed through a chromatographic capillary column in a flow of helium...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2009