Temporo-spatial cell-cycle kinetics in HeLa cells irradiated by Ir-192 high dose-rate remote afterloading system (HDR-RALS)

نویسندگان

  • Taito Asahina
  • Atsushi Kaida
  • Tatsuaki Goto
  • Ryo-Ichi Yoshimura
  • Keisuke Sasai
  • Masahiko Miura
چکیده

BACKGROUND Intracavitary irradiation plays a pivotal role in definitive radiotherapy for cervical cancer, and the Ir-192 high dose-rate remote afterloading system (HDR-RALS) is often used for this purpose. Under this condition, tumor tissues receive remarkably different absorption doses, with a steep gradient, depending on distance from the radiation source. To obtain temporo-spatial information regarding cell-cycle kinetics in cervical cancer following irradiation by Ir-192 HDR-RALS, we examined HeLa cells expressing the fluorescence ubiquitination-based cell cycle indicator (Fucci), which allowed us to visualize cell-cycle progression. METHODS HeLa-Fucci cells, which emit red and green fluorescence in G1 and S/G2/M phases, respectively, were grown on 35-mm dishes and irradiated by Ir-192 HDR-RALS under normoxic and hypoxic conditions. A 6 French (Fr) catheter was used as an applicator. A radiation dose of 6 Gy was prescribed at hypothetical treatment point A, located 20 mm from the radiation source. Changes in Fucci fluorescence after irradiation were visualized for cells from 5 to 20 mm from the Ir-192 source. Several indices, including first green phase duration after irradiation (FGPD), were measured by analysis of time-lapse images. RESULTS Cells located 5 to 20 mm from the Ir-192 source became green, reflecting arrest in G2, in a similar manner up to 12 h after irradiation; at more distant positions, however, cells were gradually released from the G2 arrest and became red. This could be explained by the observation that the FGPD was longer for cells closer to the radiation source. Detailed observation revealed that FGPD was significantly longer in cells irradiated in the green phase than in the red phase at positions closer to the Ir-192 source. Unexpectedly, the FGPD was significantly longer after irradiation under hypoxia than normoxia, due in large part to the elongation of FGPD in cells irradiated in the red phase. CONCLUSION Using HeLa-Fucci cells, we obtained the first temporo-spatial information about cell-cycle kinetics following irradiation by Ir-192 HDR-RALS. Our findings suggest that the potentially surviving hypoxic cells, especially those arising from positions around point A, exhibit different cell-cycle kinetics from normoxic cells destined to be eradicated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dose error from deviation of dwell time and source position for high dose-rate 192Ir in remote afterloading system

The influence of deviations in dwell times and source positions for (192)Ir HDR-RALS was investigated. The potential dose errors for various kinds of brachytherapy procedures were evaluated. The deviations of dwell time ΔT of a (192)Ir HDR source for the various dwell times were measured with a well-type ionization chamber. The deviations of source position ΔP were measured with two methods. On...

متن کامل

Optimization ef Dose Distribution in Intracavitary TreatmeRt of Cervical Cancer with Buchler's Afterloading System

We evaluated dose optimization for the treatment of cervical cancer using Buchler's high-dose-rate (HDR) remote-control-afterloading-system (RALS). When Buchler's system is used for intracavitary treatment, the irradiation times for the tandem and ovoid sources should be selected separately. The effects of variation of the tandem-to-ovoid dose ratio on the dose distribution are descrlbed.

متن کامل

Applicator Attenuation Effect on Dose Calculations of Esophageal High-Dose Rate Brachytherapy Using EDR2 Film

Introduction Interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. The effect of applicator attenuation is not considered in dose calculation method released by AAPM-TG43. In this study, the effect of High-Dose Rate (HDR) brachytherapy esophageal applicator on dose distribution was surveyed in HDR brachytherapy. Materials and Methods A cylindrical PMMA phan...

متن کامل

Results of radiation therapy for uterine cervical cancer using high dose rate remote after loading system.

In Japan, radiotherapy with high dose rate remote after loading system (HDR-RALS) for intracavitary brachytherapy is the standard treatment for more than 30 years. This report showed the usefulness of HDR-RALS for uterine cervical cancer. From 1980 through 1999, 442 patients with uterine cervical cancers (stage I: 66, stage II: 161, stage III: 165, stage IV: 50) were treated. Radiotherapy was p...

متن کامل

Monte Carlo calculation of the TG-43 dosimetric parameters of a new BEBIG Ir-192 HDR source.

BACKGROUND AND PURPOSE High dose rate (HDR) brachytherapy is a highly extended practice in clinical brachytherapy today. Quality dose rate distribution datasets of the HDR sources used in a clinical treatment are required. Because of the different source designs, a specific dosimetry dataset is required for each source model. In the recently published BRAPHYQS-ESTRO Report, an overview of avail...