Testing Low Doses of Caffeine on Respiratory Resistance Using the Airflow Perturbation Device

نویسندگان

  • Mary Kate Montgomery
  • Allen Luk
  • Arthur T. Johnson
  • Jafar Vossoughi
چکیده

Research reports on pulmonary function measurements often mention caffeine abstinence as a condition for testing subjects. Yet, the effects of caffeine on respiration are not well documented. This study was intended to investigate the physiological effects of caffeine on respiratory resistance measurements and the necessity of caffeine avoidance in such testing. Thirty-one subjects were administered caffeine in pill form for dosages in the range of 3 4.5 mg/kg body weight. Respiratory resistance was measured with the Airflow Perturbation Device every 15 minutes after caffeine ingestion until a full hour of elapsed time. No changes were noted in inhalation, exhalation, and average respiratory resistances during the times of measurements. The conclusion is that for low dosages of caffeine, respiratory resistance measurements are not affected by caffeine ingestion prior to testing.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Respiratory resistance measured by an airflow perturbation device.

The airflow perturbation device (APD) is an instrument for the measurement of respiratory resistance. The APD is small, lightweight, fast and requires no special breathing manoeuvres. Airflow perturbation determines resistance by superimposing a periodic signal onto spontaneous breathing with a variable resistance device. Respiratory impedance is the ratio of magnitude of pressure perturbation ...

متن کامل

Resistance Measured by Airflow Perturbation Compared with Standard Pulmonary Function Measures

Background: Routine lung function testing requires expensive equipment, or requires maximum expiratory effort. The airflow perturbation device (APD) is a light handheld device, allowing for serial measures of respiratory resistance noninvasively and effortlessly. Methods: In a convenience sample of 398 patients undergoing pulmonary function testing, we compared routine spirometric indices (forc...

متن کامل

Decrease of resistance to air flow with nasal strips as measured with the airflow perturbation device

BACKGROUND Nasal strips are used by athletes, people who snore, and asthmatics to ease the burden of breathing. Although there are some published studies that demonstrate higher flow with nasal strips, none had directly measured the effect of the strips on nasal resistance using the airflow perturbation device (APD). The APD is an inexpensive instrument that can measure respiratory resistance b...

متن کامل

تأثیر حاد تمرینات مقاومتی وامانده‌ساز و مصرف مقادیر مختلف کافئین بر پاسخ اینترلوکین-6

Background: Based on the limited and inconsistent results about the effects of acute methylxanthine component on exercise-induced inflammatory response, the present study was conducted to identify the effect of acute different doses of caffeine intake on serum interleukin-6 (IL-6) response in male volleyball players following one-session of exhaustive resistance exercise.  Methods: Thirty ma...

متن کامل

اثر کافئین بر روی یادگیری و حافظه در موش صحرایی

  The Effects of Caffeine on the Learning and Memory in Rats     AR. Vahidi PharmD1* , MH. Dasht i PhD2     1 - Academic Member, Dept. of Pharmacology, Shahid Sadoughi University of Medical sciences, Yazd, IRAN   2. Assistant Professor, Dept. of Physiology, Shahid Sadoughi University of Medical sciences , Yazd, IRAN     Background: Caffeine as a methyl xanthine compound inhibits the breakdown o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017