Retinal Vessel Oxygen Saturation during 100% Oxygen Breathing in Healthy Individuals
نویسندگان
چکیده
PURPOSE To detect how systemic hyperoxia affects oxygen saturation in retinal arterioles and venules in healthy individuals. METHODS Retinal vessel oxygen saturation was measured in 30 healthy individuals with a spectrophotometric retinal oximeter (Oxymap T1). Oximetry was performed during breathing of room air, 100% oxygen (10 minutes, 6L/min) and then again room air (10 minutes recovery). RESULTS Mean oxygen saturation rises modestly in retinal arterioles during 100% oxygen breathing (94.5%±3.8 vs. 92.0%±3.7% at baseline, p<0.0001) and dramatically in retinal venules (76.2%±8.0% vs. 51.3%±5.6%, p<0.0001). The arteriovenous difference decreased during 100% oxygen breathing (18.3%±9.0% vs. 40.7%±5.7%, p<0.0001). The mean diameter of arterioles decreased during 100% oxygen breathing compared to baseline (9.7±1.4 pixels vs. 10.3±1.3 pixels, p<0.0001) and the same applies to the mean venular diameter (11.4±1.2 pixels vs. 13.3±1.5 pixels, p<0.0001). CONCLUSIONS Breathing 100% oxygen increases oxygen saturation in retinal arterioles and more so in venules and constricts them compared to baseline levels. The dramatic increase in oxygen saturation in venules reflects oxygen flow from the choroid and the unusual vascular anatomy and oxygen physiology of the eye.
منابع مشابه
Relation of retinal blood flow and retinal oxygen extraction during stimulation with diffuse luminance flicker.
Cerebral and retinal blood flow are dependent on local neuronal activity. Several studies quantified the increase in cerebral blood flow and oxygen consumption during activity. In the present study we investigated the relation between changes in retinal blood flow and oxygen extraction during stimulation with diffuse luminance flicker and the influence of breathing gas mixtures with different f...
متن کاملRetinal oximetry measures systemic hypoxia in central nervous system vessels in chronic obstructive pulmonary disease
BACKGROUND Determination of the blood oxyhemoglobin saturation in the retinal vessels of the eye can be achieved through spectrophotometric retinal oximetry which provides access to the state of oxyhemoglobin saturation in the central nervous system circulation. The purpose of this study was to test the capability of the Oxymap T1 oximeter to detect systemic hypoxemia and the effect of suppleme...
متن کاملRetinal oxygen extraction in humans
Adequate function of the retina is dependent on proper oxygen supply. In humans, the inner retina is oxygenated via the retinal circulation. We present a method to calculate total retinal oxygen extraction based on measurement of total retinal blood flow using dual-beam bidirectional Doppler optical coherence tomography and measurement of oxygen saturation by spectrophotometry. These measuremen...
متن کاملRetinal Vascular Response to Breathing Increased Carbon Dioxide and Oxygen Concentrations.
The retina has a high rate of oxygen consumption, and the retinal vessels are knoion to constrict with increased arterial oxygen tension and dilate ivhen arterial oxygen falls. In 10 subjects, measurement of retinal venous oxygen saturation by a photographic technique has shown an increase from 55 ± 8 per cent saturation breathing air to 82 ± 9 per cent breathing 100 per cent Os. This increase ...
متن کاملShifts in retinal vessel diameter and oxygen saturation in Chinese type 2 diabetes mellitus patients
BACKGROUND The aim of this study was to analyze the shifts in retinal vessel diameter and oxygen saturation in diabetic patients with and without diabetic retinopathy (DR), as well as to assess the association between diabetes duration and either vessel diameter or oxygen saturation. METHODS In total, 99 Type 2 DM patients were recruited for the study and were divided into three groups: DM wi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 10 شماره
صفحات -
تاریخ انتشار 2015