Ultra-Low-Dose Chest CT in Patients with Neutropenic Fever and Hematologic Malignancy: Image Quality and Its Diagnostic Performance

نویسندگان

  • Hae Jin Kim
  • So Young Park
  • Ho Yun Lee
  • Kyung Soo Lee
  • Kyung Eun Shin
  • Jung Won Moon
چکیده

PURPOSE The aim of this study was to evaluate the image quality of ultra-low-dose computed tomography (ULDCT) and its diagnostic performance in making a specific diagnosis of pneumonia in febrile neutropenic patients with hematological malignancy. MATERIALS AND METHODS ULDCT was performed prospectively in 207 febrile neutropenic patients with hematological malignancy. Three observers independently recorded the presence of lung parenchymal abnormality, and also indicated the cause of the lung parenchymal abnormality between infectious and noninfectious causes. If infectious pneumonia was considered the cause of lung abnormalities, they noted the two most appropriate diagnoses among four infectious conditions, including fungal, bacterial, viral, and Pneumocystis pneumonia. Sensitivity for correct diagnoses and receiver operating characteristic (ROC) curve analysis for evaluation of diagnostic accuracy were calculated. Interobserver agreements were determined using intraclass correlation coefficient. RESULTS Of 207 patients, 139 (67%) had pneumonia, 12 had noninfectious lung disease, and 56 had no remarkable chest computed tomography (CT) (20 with extrathoracic fever focus and 36 with no specific disease). Mean radiation expose dose of ULDCT was 0.60±0.15 mSv. Each observer regarded low-dose CT scans as unacceptable in only four (1.9%), one (0.5%), and three (1.5%) cases of ULDCTs. Sensitivity and area under the ROC curve in making a specific pneumonia diagnosis were 63.0%, 0.65 for reader 1; 63.0%, 0.61 for reader 2; and 65.0%, 0.62 for reader 3; respectively. CONCLUSION ULDCT, with a sub-mSv radiation dose and acceptable image quality, provides ready and reasonably acceptable diagnostic information for pulmonary infection in febrile neutropenic patients with hematologic malignancy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment and evaluation of patient doses in adult common CT examinations towards establishing national diagnostic reference levels

Background: Patient radiation doses from computed tomography (CT) are increasing due to the number of CT examinations performed every day. The aim of this study was assess and evaluate patient radiation doses for adult’s common CT examinations to derive local diagnostic guidance levels for common CT examinations. Materials and Methods: Volume and weighted computed tomography dose index (C...

متن کامل

The Practice of Chest Radiography Using Different Digital Imaging Systems: Dose and Image Quality

Introduction: The study was undertaken to evaluate the practice of chest radiography using different digital imaging systems and its influence on dose and image quality.  Materials and Methods: The study was carried out in two hospitals from March 2016 to June 2016. Sixty ambulatory patients aged 21 to 60 years who were able to cooperate without difficulty and weighed between 60 to 80 kg were ...

متن کامل

Clinical Value of Low Dose CT- Scan in Pediatric Chest Diseases: Adequacy Assessment

Background Radiation dose about 400 times that of standard thoracic computed tomography (CT) in comparison with chest X- ray resulting in different approaches to decrease radiation dose have been established in the last few years to prevent possible side effects especially in children, such as low dose protocols. The aim of this study was assessment of clinical v...

متن کامل

Optimization of Parameters in 16-slice CT-‌‌scan Protocols for Reduction of the Absorbed Dose

Introduction In computed tomography (CT) technology, an optimal radiation dose can be achieved via changing radiation parameters such as mA, pitch factor, rotation time and tube voltage (kVp) for diagnostic images. Materials and Methods In this study, the brain, abdomen, and thorax scaning was performed using Toshiba 16-slice scannerand standard AAPM and CTDI phantoms. AAPM phantom was used for...

متن کامل

Low kilovolt “prospective ECG-triggering” vs. “retrospective ECG-gating” coronary CTA: comparison of image quality and radiation dose

Background: To compare image quality and radiation doses of low kilovolt (kV) “prospective ECG-triggering” (PT) and standard “retrospective ECG-gating” (RG) coronary computed tomography (CT) angiography. Materials and Methods: A total of 101 consecutive patients (76 males, 25 females; mean age: 55.44 ± 8.28 years) with low-to-intermediate risk status for coronary artery disease and with a body ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 46  شماره 

صفحات  -

تاریخ انتشار 2014