Comparison of heparin administration using the Rapidpoint Coag and Hepcon HMS.

نویسندگان

  • Jason Newsome
  • Kerri Stipanovich
  • Sarah Flaherty
چکیده

A retrospective chart review was conducted of patients who underwent cardiopulmonary bypass (CPB) to compare the quantities of heparin administered, postoperative blood loss, and homologous blood products transfused during their procedure and subsequent stay in the intensive care unit. The primary purpose of this review was to determine if any difference in heparin administration resulted when two different devices were used for dosing and monitoring heparin. Postoperative blood loss and amount of blood products transfused were also quantified, as any differences would potentially be a result of a difference in administration of heparin. The first group (n = 341) underwent CPB using the Hepcon HMS, Medtronic Inc., Minneapolis, MN, for heparin dosing and monitoring. The Rapid Point Coag, Bayer Healthcare LLC, Tarrytown, NY was used for the second group (n = 345). The two populations were compared for similarity on: age, body surface area (BSA), CPB time (minutes), aortic-cross clamp time (minutes), baseline activated clotting time, and baseline hematocrit. No significant difference was found between the two groups. The second group, using the Rapidpoint Coag, received less heparin during CPB than the group using the Hepcon HMS. In addition, there were decreases in amounts of some blood products transfused as well as mediastinal drainage from the Hepcon HMS to the Rapidpoint Coag group. A summary of the findings can be found in Table 1. A secondary purpose of this study was to determine the influence of hemodilution on the Heparin Management Test (HMT). Citrated whole blood was diluted to varying degrees at various concentrations to determine whether hemodilution with crystalloid would alter the HMT measurements. At all heparin levels and degrees of dilution, the HMT remained stable, with coefficients of variation (CV) of less than 5% at all heparin levels even while incorporating excessive crystalloid dilution (up to 75%).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved protamine-sensitive membrane electrode for monitoring heparin concentrations in whole blood via protamine titration.

An improved protamine-sensitive electrode based on a polymeric membrane doped with the charged ion exchanger dinonylnaphthalenesulfonate (DNNS) is used for monitoring heparin concentrations in whole blood. The electrode exhibits significant nonequilibrium potentiometric response to polycationic protamine over the concentration range of 0.5-20 mg/L in undiluted whole-blood samples. The sensor ca...

متن کامل

The effects of protamine overdose on coagulation parameters as measured by the thrombelastograph.

BACKGROUND AND OBJECTIVE Protamine is routinely administered following cardiopulmonary bypass in order to neutralize the effects of heparin. An excess of protamine can contribute to coagulopathy, hence predisposing to bleeding with associated morbidity and mortality. Thromboelastography (TEG) is recognized as an invaluable bedside tool to detect coagulation parameters; however, the effects of p...

متن کامل

Heparin and Protamine Titration Does Not Improve Haemostasis after Cardiac Surgery: A Prospective Randomized Study

BACKGROUND Bleeding complications are common in cardiac surgery. Perioperative handling of heparin and protamine may influence the haemostasis. We hypothesized that heparin and protamine dosing based on individual titration curves would improve haemostasis in comparison to standard dosing. SUBJECTS AND METHODS Sixty patients scheduled for first time elective coronary artery bypass grafting or...

متن کامل

Comparison between complications of vascular surgery procedures with and without aPPT assessment and protamine sulfate reversal

 Abstract Background: Thrombosis will occur due to contact of blood with unepithelialized surfaces after vascular clamping and also blood stasis during vascular surgery. Heparin is administered to prevent thrombosis. The aPTT test is used for assurance of the anticoagulative effect of heparin. At the end of the operation heparin is neutralized by protamine sulfate in some centers. In this study...

متن کامل

Generation of Mature Monocyte-Derived Dendritic Cells in the Presence of Heparin and Monocyte Conditioned Medium: Phenotypic and Functional Comparison

Background: Dendritic cells (DC) induce tumor or pathogen-specific T cell responses in humans. Several laboratories have developed culture systems, including maturation factors for human DC from peripheral blood monocytes. We comprehensively compared standard maturation stimulus, an autologous monocyte-conditioned medium (MCM), with heparin for their ability to promote uniformly mature DC that ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 36 2  شماره 

صفحات  -

تاریخ انتشار 2004