Development of the smartphone-based colorimetry for multi-analyte sensing arrays.

نویسندگان

  • Jong Il Hong
  • Byoung-Yong Chang
چکیده

Here we report development of a smartphone app (application) that digitizes the colours of a colorimetric sensor array. A conventional colorimetric sensor array consists of multiple paper-based sensors, and reports the detection results in terms of colour change. Evaluation of the colour changes is normally done by the naked eye, which may cause uncertainties due to personal subjectivity and the surrounding conditions. Solutions have been particularly sought in smartphones as they are capable of spectrometric functions. Our report specifically focuses on development of a practical app for immediate point-of-care (POC) multi-analyte sensing without additional devices. First, the individual positions of the sensors are automatically identified by the smartphone; second, the colours measured at each sensor are digitized based on a correction algorithm; and third, the corrected colours are converted to concentration values by pre-loaded calibration curves. All through these sequential processes, the sensor array taken in a smartphone snapshot undergoes laboratory-level spectrometry. The advantages of inexpensive and convenient paper-based colorimetry and the ubiquitous smartphone are tied to achieve a ready-to-go POC diagnosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fusion of microlitre water-in-oil droplets for simple, fast and green chemical assays.

A simple format for microscale chemical assays is proposed. It does not require the use of test tubes, microchips or microtiter plates. Microlitre-range (ca. 0.7-5.0 μL) aqueous droplets are generated by a commercial micropipette in a non-polar matrix inside a Petri dish. When two droplets are pipetted nearby, they spontaneously coalesce within seconds, priming a chemical reaction. Detection of...

متن کامل

Development of a Disposable Electrochemical Sensor based on Nanocomposite/Ionic Liquid Assisted Hollow Fiber-Graphite Electrode for Measurement of Lorazepam Using Central Composite Design

In this study a new method of preconcentration, separation and efficient measuring of so-called hollow fiber solid / liquid phase microextraction has been introduced for the determination of trace amounts of lorazepam (LRZ) in water samples, urine and hair using differential pulse voltammetry. To this end, a hybrid adsorbent material was used that involved ionic liquid assisted magnetic multi-w...

متن کامل

Simple and Highly-sensitive Enzyme Activity Assay Based on Reagent-release Capillary - Isoelectric Focusing (rrc-ief) towards the Development of Multi Analyte Sensing Micro Device Capable of Detecting Both Proteins and Enzyme Activities

We developed a simple and highly-sensitive enzyme activity assay method based on reagent release capillary – isoelectric focusing (RRC-IEF), that can be applied for the development of multi analyte sensing device allowing simple and highly sensitive multi assay of both proteins and enzyme activities.

متن کامل

Optical sensor arrays for chemical sensing: the optoelectronic nose.

A comprehensive review is presented on the development and state of the art of colorimetric and fluorometric sensor arrays. Optical arrays based on chemoresponsive colorants (dyes and nanoporous pigments) probe the chemical reactivity of analytes, rather than their physical properties. This provides a high dimensionality to chemical sensing that permits high sensitivity (often down to ppb level...

متن کامل

Resolving Spectra Overlapping Based on Net Analyte Signal for Simultaneous Spectrophotometric Determination of Fluoxetine and Sertraline

The net analyte signal standard addition method was used for simultaneous spectrophotometric determination of sertraline and fluoxetine in pharmaceutical preparations. The method combines the advantages of the standard addition method with the net analyte signal concept to enable the extraction of information about an analyte from the spectra of multi-component mixtures. This method uses full s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lab on a chip

دوره 14 10  شماره 

صفحات  -

تاریخ انتشار 2014