Unbonded Post Tensioned Concrete Slabs in Fire – Part II – Modelling Tendon Response and the Consequences of Localized Heating
نویسندگان
چکیده
This is Part II of a two part paper dealing with the current state of knowledge of the fire-safe structural design and construction of unbonded post-tensioned (UPT) flat plate concrete structures. Part I provided detailed results of nineteen transient high temperature stress relaxation tests on restrained UPT tendons of realistic length and parabolic longitudinal profiles. Experimentation identified several credible concerns for UPT concrete structures in fire, most notably the potential for premature tendon rupture due to localized heating, which may result from a number of possible causes in a real structure. The real world response of continuous UPT tendons both during and after heating is largely unknown, and is dependent on factors which are not currently accounted for either in standard fire tests or by available prescriptive design guidance. This second part of the paper presents and applies a numerical model to predict the time-temperature-stress-strength interdependencies of stressed UPT tendons under localized transient heating, as may be experienced by tendons in a real concrete building in a real fire. The model is used, along with previously developed and validated computational models for heat transfer and prestress relaxation in UPT tendons, to assess existing prescriptive concrete cover requirements for UPT slabs. It is shown that localized heating of UPT tendons is likely to induce premature tendon rupture during fire, and that current prescriptive code procedures based on concrete cover alone are, in general, insufficient to prevent this. Based on the data presented it appears that minimum code prescribed concrete covers for UPT structures require revision if premature tendon rupture during fire is to be avoided.
منابع مشابه
Transient High-temperature Stress Relaxation of Prestressing Tendons in Unbonded Construction
Unbonded post-tensioned (UPT) flat plate concrete slabs are popular for modern continuous multiple bay floor assemblies due to economic and sustainability benefits (reductions in slab thickness and building selfweight) and structural advantages (decreased deflections over larger spans). Only limited research has been conducted on the performance of UPT flat plate slabs under fire conditions, ye...
متن کاملUltimate Unbonded Tendon Stress in CFRP Strengthened Post-Tensioned Indeterminate I-Beams Cast with HSCs
Based on the bending experiment for two-span continuous post-tension beams with unbounded tendons and externally applied CFRP sheets, the analysis of the stress increment of unbonded tendons is monitored in the loading process. Since self-compacting concrete (SCC) is a suitable innovation,, understanding the implementation of this type of concrete on the ultimate unbonded tendon stress is criti...
متن کاملServiceability Response of Rehabilitated Unbonded Post-tensioned Indeterminate I-Beams Consisting UHSSCC
The ultra-high strength self-compacting concrete, UHSSCC is the new generation type of concrete with a compressive strength higher than 80MPa. The application of this type of concrete on the serviceability state in CFRP strengthened unbonded post-tensioned indeterminate I-beam is monitored and the results are compared theoretically using different standards. For this aim, full scale I-beam of 9...
متن کاملUnbonded Post Tensioned Concrete in Fire: A Review of Data from Furnace Tests and Real Fires
The fire-safe design of concrete structures which incorporate post-tensioned prestressing tendons has recently been the subject of debate within the structural engineering community, particularly when unbonded post-tensioned (UPT) prestressing tendons are used. Despite several studies aimed at furthering our understanding of the response of UPT concrete structures in fire, many aspects of their...
متن کاملUltimate Tendon Stress in CFRP Strengthened Unbounded HSC Post-Tensioned Continuous I-Beams
The use of unbounded tendons is common in prestressed concrete structures and evaluation of the stress increase in unbonded tendons at ultimate flexural strength of such structure has posed a great challenge over the years. Based on the bending experiment for two-span continuous post-tension beams with unbounded tendons and externally applied CFRP sheets, the monitoring of the stress increment ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -