Modelling High Pressure Flow and Replacement of Pipes in Water Supply Systems in North Portugal

نویسندگان

  • L. F. SANCHES FERNANDES
  • A. PINTO
چکیده

Public water supply networks in Portugal do not have, in general terms, management and monitoring systems, either at the level of quality or at the level functioning of the hydraulic system itself (pressures, speeds, water leaks and losses, among others). In order for any management system to function, it is obviously necessary that its physical features are known, which does not occur in most cases. For instance, the record of the supply networks and branchlines of connection to consumers are unknown, and the same occurs regarding the features of the material used (type of material, diameters, accessories, among others), that is, it completely derails the implementation of any software that may be able to help the managing entities of these water supply systems that are mostly Municipalities or, at times, concessionary companies. The study presented hereafter was carried out in two cities in North Portugal and intends to demonstrate the usefulness of an effective system that has the potential to manage water supply networks. In both cities, target areas of this study were delimited (each one with over 6 000 inhabitants, this being one of the assumptions of the software used). Another particularity is that in the city of Vila Real, the water supply system is managed by the Municipality, whereas in the city of Fafe, it is managed by a concessionary company, “Indaqua”. After the sub-systems were physically designed, the simulations that proved more beneficial were the ones that consider Pressure Reducing Valves (PRV’s), as North Portugal is rather rough in topographical terms, which causes exaggerated pressures on the pipes, frequently exceeding the limit allowed by the Portuguese Law (600 KPa). Among other simulations that have been performed, this was, in fact, the one that clearly and objectively allowed engineers to know where the location should be or locations to place these PRV’s in the sub-systems of both cities. The replacement of pipe sections was also one of this work’s approaches, since it is urgent to deactivate many pipes that are degraded and obstructed. With the simulations performed, it will be possible to analyse which is the system’s hydraulic behaviour and which will be the impact (social, for instance) of the deactivation of some sections. Keywords– Monitoring, management, pressure, Epanet, GIS

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی میزان حوادث و تلفات آب در شبکه توزیع آب شرب شهر ازنا و عوامل موثر بر آن در سال‌های 1387تا1393

Introduction and purpose: One of the problems of water distribution systems is loss of large volumes of water due to the occurrence of various events, which incurs a huge financial loss. Regarding this, the aim of the present study was to investigate the rate of events and water loss in the water distribution system and its related factors in Azna, Lorestan province, Iran, d...

متن کامل

Experimental Results of Pressure Fluctuations in a Water Conduit Section Due to Formation of Unstable Two-Phase Air-Water Flow

The study of two-phase fluid flow behavior in hydraulic structures such as pressurized flow tunnels, culverts, sewer pipes, junctions and other similar conduits is of great importance. A two-phase mixture flowing in a pipe can exhibit several interfacial geometries such as bubbles, slugs or films, depending on the fluid and hydrodynamic properties of flow. The main variables, giving rise to a v...

متن کامل

Experimental Results of Pressure Fluctuations in a Water Conduit Section Due to Formation of Unstable Two-Phase Air-Water Flow

The study of two-phase fluid flow behavior in hydraulic structures such as pressurized flow tunnels, culverts, sewer pipes, junctions and other similar conduits is of great importance. A two-phase mixture flowing in a pipe can exhibit several interfacial geometries such as bubbles, slugs or films, depending on the fluid and hydrodynamic properties of flow. The main variables, giving rise to a v...

متن کامل

The Influence of the Pipe’s Material and the Mass Flow Rate on the Pressure Drop and Velocity Variation During Pneumatic Conveying of Wheat Using Computational Fluid Dynamics

According to flexibility of pneumatic conveying systems with respect to other types of transmission systems, this system has wide application in industry and agriculture processes. One important application of this system is in the loading and unloading tankers and powdery bulk materials such as trucks carrying cement, plaster and sand. Conveying efficiency is associated with pressure, which in...

متن کامل

The Influence of the Pipe’s Material and the Mass Flow Rate on the Pressure Drop and Velocity Variation During Pneumatic Conveying of Wheat Using Computational Fluid Dynamics

According to flexibility of pneumatic conveying systems with respect to other types of transmission systems, this system has wide application in industry and agriculture processes. One important application of this system is in the loading and unloading tankers and powdery bulk materials such as trucks carrying cement, plaster and sand. Conveying efficiency is associated with pressure, which in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012