A Comparative Evaluation of the Differential-pressure-based Respirable Dust Dosimeter with the Personal Gravimetric Respirable Dust Sampler in Underground Coal Mines

نویسندگان

  • R. V. Ramani
  • J. M. Mutmansky
  • Honglin He
چکیده

The development of a sampling instrument for the assessment of an underground coal miner’s exposure to airborne respirable coal mine dust on a continuous and real-time basis has been long identified as essential for timely initiation of control actions. A respirable dust dosimeter (RDD) which operates on the principle of increasing pressure across a filter media with increasing dust mass on the filter has been developed by the National Institute for Occupational Safety and Health. Comparisons of the performance of the RDD with an U.S. approved gravimetric respirable dust sampler (GRD) have shown that the RDD may meet the requirements for measuring miners’ exposures on a cumulative, near real-time basis such as mid-shift and end of shift exposures. Recently, the performances of the RDD and GRD were compared by conducting side-by-side area sampling experiments in a controlled experimental environment in the laboratory and in underground coal mines under normal operating conditions. In this paper, the results from the in-mine study are presented and discussed. The experimental design for the inmine study included two mines in different coal seams in different geographic coal regions. To ensure a wide range of concentrations, the experiments were conducted in a continuous miner section in Mine 1, and a longwall face in Mine 2. Airborne dust sampling was conducted for four different shifts at each mine. In each shift, two samples of different exposure durations were collected from two different locations. Each sample consisted of the readings of three dosimeters and the exposed filters from the three paired GRD samplers. As a result, a total of 96 comparative samples were obtained, 48 for each mine. The data were analyzed for the precision of the RDD and GRD measurements and for the relationships between the differential pressure of the RDD and the mass of dust on the paired GRD filter. The analyses indicate that, on the average, the RDD and the GRD track the airborne respirable dust concentrations well, exhibiting both a high correlation between the two measurements and a reliable predictive relationship of one from the other. Details of the experimental design, data analyses procedures, results, conclusions and recommendations of the underground experiments are presented in this paper.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laboratory evaluation of pressure differential-based respirable dust detector tube.

Assessment of exposure to occupational dusts is a first step in reducing exposures to harmful dust concentrations. A new type of respirable dust sampler was developed and compared side-by-side to personal gravimetric samplers in the laboratory. The new sampler correlates filter back pressure with mass accumulation to provide mid-shift- and end-of-shift determinations of cumulative exposure. The...

متن کامل

Equivalency of a personal dust monitor to the current United States coal mine respirable dust sampler.

The United States National Institute for Occupational Safety and Health, through an informal partnership with industry, labor, and the United States Mine Safety and Health Administration, has developed and tested a new instrument known as the Personal Dust Monitor (PDM). The new dust monitor is an integral part of the cap lamp that coal miners normally carry to work and provides continuous info...

متن کامل

Assessment of respirable dust and its free silica contents in different Indian coalmines.

Assessment of respirable dust, personal exposures of miners and free silica contents in dust were undertaken to find out the associated risk of coal workers' pneumoconiosis in 9 coal mines of Eastern India during 1988-91. Mine Research Establishment (MRE), 113A Gravimetric Dust Sampler (GDS) and personal samplers (AFC 123), Cassella, London, approved by Director General of Mines Safety (DGMS) w...

متن کامل

Study to Assess Respirable Dust Exposures in Underground U.S. Coal Mines

In 1991 the Mine Safety and Health Administration conducted a special program to assess occupational exposures to respirable coal mine dust in underground coal mines. Priority was given to longwall mining operations, mines with a history ofhaving a problem controlling dust to the applicable standard, and a representative number of all other mines. Measurements were obtained on approximately 720...

متن کامل

Evaluation of occupational exposures to respirable dust in underground coal mines.

Dust can be produced by almost all mining operations in underground coal mines and seen all around the mine. Different occupational groups get exposed to different dust levels and in order to minimize the probability of developing coal workers' pneumoconiosis (CWP), it is necessary to investigate the workers exposed to dust. This study aimed to evaluate the dust concentration conditions in unde...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001