Development of rapid plutonium analysis for environmental samples by isotope dilution/inductively coupled plasma mass spectrometry with on-line column.

نویسندگان

  • Yoshihito Ohtsuka
  • Yuichi Takaku
  • Jyoji Kimura
  • Shun'ichi Hisamatsu
  • Jiro Inaba
چکیده

This paper describes our development of a rapid on-line column/ID-ICP-MS technique for the analysis of plutonium (Pu) in environmental samples using an UTEVA extraction chromatograph resin (UTEVA resin) column. It took only 40 min to separate and measure Pu in the sample solution, including the time for conditioning the resin column for the next analysis. In our method, Pu in a 3 M nitric acid solution was fed to the UTEVA resin, and then eluted from the resin by reducing Pu to Pu(III) with 3 M nitric acid mixed with 0.01 M ascorbic acid after washing the resin. The outflow from the resin column was directly introduced to an ICP-MS system. The low concentration of ascorbic acid and the small volume of the eluting solution (0.6 mL) made successive stable analysis possible without any skimmer cone clogging. The chemical recovery of Pu during column operation was 70%, and typical lower detection limits for 239Pu, 240Pu and 242Pu were 9.2, 4.3 and 7.5 fg (21, 36 and 1.1 microBq), respectively. We analyzed five international standard materials for Pu, and obtained good results.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of 137Ba Isotope Abundances in Water Samples by Inductively Coupled Plasma-optical Emission Spectrometry Combined with Least-squares Support Vector Machine Regression

A simple and rapid method for the determination of 137Ba isotope abundances in water samples by inductively coupled plasma-optical emission spectrometry (ICP-OES) coupled with least-squares support vector machine regression (LS-SVM) is reported. By evaluation of emission lines of barium, it was found that the emission line at 493.408 nm provides the best results for the determination...

متن کامل

Plutonium, protactinium, uranium and thorium isotopes determination in environmental samples by SF ICP-MS

Alpha spectrometry is the most commonly used analytical tool for the determination of Pu, Am, Pa, U and Th long live radionuclides. Thermal ionization mass spectrometry (TIMS) and acceleration mass spectrometry (AMS) are also still considered as primary methods for the determination of their isotope ratios. Spectrometers with plasma ion sources now offer another efficient alternative method wit...

متن کامل

The Analysis of Pu Isotopes in Seawater by Flow Injection High Resolution Inductively Coupled Plasma Mass Spectrometry

INTRODUCTION To estimate the long-term radiation dose to man due to artificial radionuclides, a detailed knowledge of their distribution in the environment is indispensable. From the viewpoint of toxicity and radiation damage to the human being, plutonium is by far the most important nuclide of the transuranic elements that has been released into the environment by nuclear weapons tests, satell...

متن کامل

Isotopic analysis of uranium and plutonium using ICP-MS and estimation of burn-up of spent uranium in contaminated environmental samples{

Environmental monitoring of actinides and evaluation of the contamination source (nuclear weapons tests, nuclear power plant and nuclear reprocessing plant accidents, etc.) requires precise and accurate isotopic analysis of actinides, especially uranium and plutonium. Double-focusing sector-field inductively coupled plasma mass spectrometry (ICP-SFMS) using a low-flow microconcentric nebulizer ...

متن کامل

Validation of Bulk Analysis with Simulated Swipe Samples Containing Ultra- Trace Amounts of Uranium and Plutonium Using MC-ICP-MS

Suitable analytical procedures for the bulk analysis of ultra-trace amounts of uranium and plutonium have been developed using multi-collector inductively coupled mass spectrometry (MC–ICP–MS). The quantification and determination of the isotopic ratios of uranium and plutonium in three simulated swipe samples, a swipe blank, and a process blank were performed to validate the analytical perform...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 21 3  شماره 

صفحات  -

تاریخ انتشار 2005