Effect of water storage on tooth displacement in maxillary complete dentures.

نویسندگان

  • Rafael Leonardo Xediek Consani
  • Marcelo Ferraz Mesquita
  • Simonides Consani
  • Lourenço Correr Sobrinho
  • Manoel Damião Sousa-Neto
چکیده

The purpose of this study was to investigate the effect of water storage at 37 degrees C (1 week, 1 month and 3 months) on tooth displacement in maxillary complete dentures. Ten maxillary dentures were constructed with Clássico acrylic resin using the conventional method of packing in metallic flasks. Metallic reference pins were placed in the incisal border of the central incisors (I), labial cusp of the first premolars (PM), and mesiolabial cusp of the second molars (M). Twelve hours after final flask closure, the acrylic resin was cured in water at 74 degrees C for 9 h. The flasks were removed from the thermo-polymerizing unit after water-cooling and the dentures were deflasked, finished and stored in water at a temperature of 37 degrees C for 1 week, 1 month and 3 months. At deflasking and at the water storage intervals, the I-I (incisor to incisor), PM-PM (pre-molar to pre-molar), and M-M (molar to molar) transversal distances, and LI-LM (left incisor to left molar) and RI-RM (right incisor to right molar) anteroposterior distances were measured using an optical microscope with 0.0005 mm accuracy. Data were submitted to ANOVA and Tukey's test (5%). Comparing the evaluation periods for each individual transversal and anteroposterior reference point, no statistically significant differences were observed among deflasking and the water storage intervals for I-I, PM-PM, M-M and RI-RM distances (p>0.05). For LI-LM, however, deflasking values were statistically different from those of 1-week, 1-month and 3-month water storage intervals (p<0.05), which, in turn, did not differ statistically to each other (p>0.05). These results confirm the complexity of tooth displacement in complete dentures. From a clinical standpoint, the difference observed in LI-LM distance after water storage would not be detected by the patients during clinical use.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dimensional stability of distances between posterior teeth in maxillary complete dentures.

The aim of this study was to assess the displacement of posterior teeth in maxillary complete dentures stored in water at 37 degrees C. Twenty acrylic resin-based maxillary complete dentures were constructed with the anterior teeth arranged in normal overlap and the posterior teeth in Angle class I. Metallic pins were placed on the labial cusp of the first premolars (PM), and on the mesiolabial...

متن کامل

Relationship between Length and Width of Maxillary Central Teeth and Facial Indices in Patients with Complete Denture

 Background and purpose: In tooth selection for dentures, the size of the tooth is really important. To estimate the size, a group of landmarks of the face have been investigated. This study evaluated the relationship between the length and width of maxillary central incisors and measurable indices of the face in patients with complete denture. Materials and methods: A descriptive-analytic cro...

متن کامل

Influence of the Deflasking Delay Time on the Displacements of Maxillary Denture Teeth Influência Do Tempo De Demora Para Desinclusão Nos Deslocamentos Dentais Em Prótese Total Superior

he purpose of this study was to investigate the displacement of teeth occurring in dentures following storage in water at a temperature of 37oC. Ten maxillary dentures were constructed with Classico heat-cured acrylic resin using conventional metal flasks. Metallic reference pins were placed on the incisal border of the central incisors (I), buccal cusp of the first premolars (PM), and mesiobuc...

متن کامل

Effect of monomer content in the monomer-polymer ratio on complete denture teeth displacement.

The purpose of the study was to verify the linear displacement of teeth in maxillary complete dentures influenced by different monomer-polymer ratios - according to the manufacturer's instructions, with 25% excess or 25% less monomer content - in the conventional and microwaved polymerization techniques. Wax base plates and wax planes were made on edentulous maxillary stone casts according to t...

متن کامل

Effect of Stone Cast Type on Complete Denture Base Adaptation

Introduction: Few researches have been conducted researches on the influence of the type of dental stone used for fabrication of casts on the adaptation of denture bases. The purpose of this study was to compare the effect of two types of stone casts on the accuracy of fit in complete denture bases. Methods: Using sixty fully replicated master casts obtained by duplicating a metal die represent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Brazilian dental journal

دوره 17 1  شماره 

صفحات  -

تاریخ انتشار 2006