Accuracy of Round Meter Gates for On-Farm Deliveries
نویسنده
چکیده
Recent California legislation requires irrigation water agencies larger than 25,000 acres to measure volumetric water deliveries within specified levels of relative uncertainty. Although the meter gate is one of the most widely used flow measurement devices in California, little investigation has been conducted into the accuracy, limitations, and uncertainties of the rating tables developed over 60 years ago. A meter gate testing facility was constructed at the Cal Poly Irrigation Training and Research Center’s Water Resources Facility capable of testing gates up to 0.76 m (30 in.). The facility was constructed with gates oriented perpendicular to the supply channel flow to match actual field conditions. Three commonly used gate sizes of 0.30 m (12 in.), 0.46 m (18 in.), and 0.61 m (24 in.) were examined under a variety of upstream head, head loss, and gate opening conditions. Based on the limitations, guidelines are included to assist users and lower the uncertainty of these devices. It was found that meter gates can be an accurate flow measurement device if installed and operated correctly according to guidelines provided. Limitations were found: upstream head above the top of the turnout pipe must be maintained equivalent to at least half the pipe diameter, and gate openings less than 25% open can lead to large uncertainties. Using the new rating tables for the three gates examined, the relative uncertainty is less than ±5 to ±7% at the 95% confidence level with the new rating tables, as compared with less than ±10% at a 95% confidence level using common published tables. Uncertainties are lower than the required estimated 10.7% instanta neous flow rate uncertainty that will be needed to meet current SB X7-7 requirements.
منابع مشابه
Rating Rectangular Farm Delivery Meter Gates for Flow Measurement
Traditional meter gates for farm delivery flow measurement from an open channel conveyance have traditionally incorporated round canal gates (Armco type) for control. In recent years, some irrigation water agencies (i.e., irrigation districts) have replaced deteriorating round gates with lower-cost rectangular gates that cover round holes. Similar to the situation described in a companion paper...
متن کاملLevel of exposure to X-Ray in security gates of Tehran’s Imam Khomeini airport
X-Ray is an ionizing electromagnetic radiation with a wide spectrum. A setting where this radiation is widely used is airport security units. This study was conducted to measure the level of momentary exposure to X-Ray in operators and personnel working in security gates of Imam Khomeini airport. In this cross-sectional study, the X-Ray machines used in security gates of Imam Khomeini airport a...
متن کاملA novel design for all-optical NAND/NOR/XOR gates based on nonlinear directional coupler
In this paper a novel all-optical logic NAND, NOR and XOR gate based on nonlinear directional coupler theory is demonstrated. We use the identical structure which contains three waveguides, for designing these gates; the only difference however, is the power of inputs light beam. In other words, while a beam with 4 W/μm in power considered as logical one, the output is NAND gate and if a beam w...
متن کاملA novel design for all-optical NAND/NOR/XOR gates based on nonlinear directional coupler
In this paper a novel all-optical logic NAND, NOR and XOR gate based on nonlinear directional coupler theory is demonstrated. We use the identical structure which contains three waveguides, for designing these gates; the only difference however, is the power of inputs light beam. In other words, while a beam with 4 W/μm in power considered as logical one, the output is NAND gate and if a beam w...
متن کاملOptimal Current Meter Placement for Accurate Fault Location Purpose using Dynamic Time Warping
This paper presents a fault location technique for transmission lines with minimum current measurement. This algorithm investigates proper current ratios for fault location problem based on thevenin theory in faulty power networks and calculation of short circuit currents in each branch. These current ratios are extracted regarding lowest sensitivity on thevenin impedance variations of the netw...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2015