Evaluation of the accuracy and angular resolution of q-ball imaging

نویسندگان

  • Kuan-Hung Cho
  • Chun-Hung Yeh
  • Jacques-Donald Tournier
  • Yi-Ping Chao
  • Jyh-Horng Chen
  • Ching-Po Lin
چکیده

Q-ball imaging (QBI) has been proposed for the mapping of multiple intravoxel fiber structures using the Funk-Radon transform on high angular resolution diffusion images (HARDI). However, the accuracy and the angular resolution of QBI to define fiber orientations and its dependence on diffusion imaging parameters remain unclear. The phantom models, made up of sheets of parallel capillaries filled with water, were designed to evaluate the accuracy and the angular resolution of QBI at different |q| values. With an inner diameter of 20 mum and an outer diameter of 90 mum, the capillaries afforded a restrictive environment compared with the diffusion measurement scale. Further, the angular resolutions of QBI at various |q| value were also quantified on the corpus callosum in the human brain. The full width at half maximum (FWHM) of the main lobe of normalized orientation distribution function (nODF) was calculated and adopted to quantify the angular resolution of QBI. With the phantom model, a higher |q| value resulted in worse accuracy but better angular resolution for QBI. The same trend where a higher |q| value yielded a better angular resolution was also observed in the human study. Upon comparison of QBI with T2WI, QBI with |q|=277 cm(-1) (b=3000 s/mm(2)) was found to be insufficient to differentiate capillaries crossing at 45 degrees . However, when encoding with |q|=320, 358, and 392 cm(-1) (b=4000, 5000, and 6000 s/mm(2)), the deviation angles between the primary ODF and the 45 degrees phantoms were -4.91 degrees +/-2.72 degrees , -1.37 degrees +/-2.32 degrees , and -0.69 degrees +/-1.54 degrees with adequate signal-to-noise ratio (SNR). These results were consistent with the FWHM-nODF, which showed that a |q| value of 320 cm(-1) was the threshold to resolve capillaries intersecting at 45 degrees . Additionally, it was demonstrated in both the phantom model and the human brain that QBI encoding with lower |q| values may result in underestimation of the orientations of the crossing fibers. In conclusion, QBI was found to accurately resolve crossing fiber orientations and was highly dependent on the selected |q| value.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Fiber Direction in High Angular Resolution Diffusion Images using Spherical Harmonics Functions and Wiener Filter

Diffusion tensor imaging (DTI) MRI is a noninvasive imaging method of the cerebral tissues whose fibers directions are not evaluated correctly in the regions of the crossing fibers. For the same reason the high angular resolution diffusion images (HARDI) are used for estimation of the fiber direction in each voxel. One of the main methods to specify the direction of fibers is usage of the spher...

متن کامل

Methods to Improve Fiber Reconstruction at DTI-Based Tractography in the Area of Brain Tumor: Case Illustration and Literature Review

Background and Aim: DTI-based tractography could help us to visualize the spatial relation of fiber tracts to brain lesions. Several factors may interfere with the procedure of diffusion-based tractography, especially in brain tumors. The aim of the current study is to discuss several solutions to improve the procedure of fiber reconstruction adjacent or inside brain lesions. Illustrative cases...

متن کامل

Optimization of diffusion spectrum imaging and q-ball imaging on clinical MRI system

Mapping complex crossing fibers using diffusion MRI techniques requires adequate angular precision and accuracy. Beyond diffusion tensor imaging (DTI), high angular resolution sampling schemes such as diffusion spectrum imaging (DSI) and q-ball imaging (QBI) were proposed to resolve crossing fibers. These schemes require hundreds of data approximately five to ten times more than DTI, offsetting...

متن کامل

Diagnostic Accuracy of Different Resolutions of Cone Beam Computed Tomography Imaging System for Detection of Vertical Root Fractures In Presence of Casting Posts

  Objective: The diagnosis of vertical root fracture (VRF) in endodontically treated teeth is a clinical challenge due to lack of specific clinical and radiographic signs. Although radiographic evaluation such as CBCT is helpful, intracanal posts can produce artifacts and may impair the quality of CBCT scans. This study aimed to compare the diagnostic accuracy of different resolutions of CBCT i...

متن کامل

Dataset-independent reconstruction of high angular resolution diffusion sampling schemes by generalized q-space imaging

We propose a novel q-space imaging method called generalized q-space imaging (GQI), which is derived from the Fourier transform relationship between the MR signals and underlying diffusion displacement [1]. The method is characterized by being independent of the q-space sampling schemes, enabling us to use either q-ball imaging (QBI) [2] or diffusion spectrum imaging (DSI) dataset [3]. The accu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • NeuroImage

دوره 42 1  شماره 

صفحات  -

تاریخ انتشار 2008