Elevated chromium levels and prosthetic joint implants.

نویسنده

  • James William Price
چکیده

Chromium is a naturally occurring, toxic heavy metal used in many industrial processes. The U.S. Department of Labor's Occupational Safety and Health Administration has established specific limits for occupational exposure levels of chromium and guidelines for medical surveillance of individuals who have been exposed to chromium. The author presents a case in which a 54-year-old man who had been working with chromium exhibited persistent elevations of urinary chromium levels after the cessation of occupational exposure. The author determined that the elevated chromium levels were caused by the patient's knee prostheses, which were made of cobalt-chromium alloy. The author also discusses mandates and screening guidelines for occupational chromium exposure and reviews the literature on chromium levels in individuals with prosthetic joint implants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of Environmental Factors and Relationships between Vanadium, Chromium, and Calcium in Human Bone

The aim of this study was to investigate the impact of environmental factors on the concentrations of vanadium (V), chromium (Cr), and calcium (Ca) and to examine the synergistic or antagonistic relationships between these metals, in cartilage (C), cortical bone (CB), and spongy bone (SB) samples obtained following hip joint surgery on patients with osteoarthritis in NW Poland. We found signifi...

متن کامل

Metal ion levels after metal-on-metal proximal femoral replacements: a 30-year follow-up.

Metal-on-metal hip bearings are being implanted into younger patients. The consequence of elevated levels of potentially carcinogenic metal ions is therefore a cause for concern. We have determined the levels of cobalt (Co), chromium (Cr), titanium (Ti) and vanadium (Va) in the urine and whole blood of patients who had had metal-on-metal and metal-on-polyethylene articulations in situ for more ...

متن کامل

The potential role of metal ion release as a marker of loosening in patients with total knee replacement: a cohort study.

We investigated the role of ion release in the assessment of fixation of the implant after total knee replacement and hypothesised that ion monitoring could be a useful parameter in the diagnosis of prosthetic loosening. We enrolled 59 patients with unilateral procedures and measured their serum aluminium, titanium, chromium and cobalt ion levels, blinded to the clinical and radiological outcom...

متن کامل

Metallosis of the Resurfaced Hip

Metallosis of the hip is usually defined as aseptic fibrosis, local necrosis, or loosening of the prosthesis secondary to metallic corrosion and release of wear debris.8 It has also been defined as gray discoloration of the tissues of the joint, pain, an effusion, and elevated serum metal levels. Metallosis has been found with stainless steel, titanium, and cobalt chromium alloy femoral prosthe...

متن کامل

Total Knee Arthroplasty Failure Induced by Metal Hypersensitivity

BACKGROUND Metal hypersensitivity is an uncommon complication after total knee arthroplasty (TKA) that can lead to significant functional impairment and aseptic prosthesis failure. CASE REPORT We describe a 70-year-old patient who presented with persistent pain, swelling, and instability 2 years after a primary TKA. The patient had a history of metal hypersensitivity following bilateral metal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of the American Osteopathic Association

دوره 111 9  شماره 

صفحات  -

تاریخ انتشار 2011