Limit State Evaluation for Transmission Tower-Line System
نویسندگان
چکیده
The physical infrastructure of the power systems, including the high-voltage transmission towers and lines as well as the poles and wires for power distribution at a lower voltage level, is critical for the resilience of the community to avoid power outages under the extreme weather related loads. In the current engineering practices, single circuit lattice steel towers linked by transmission lines are widely used to form power transmission systems. This study is to develop a limit state evaluation method for typical transmission tower-line system subjected to strong wind loadings. Wind tunnel experiments were carried out to obtain the drag coefficients for different panels of the transmission towers as well as for the transmission lines. Incremental dynamic analysis (IDA) is carried out to find the capacity curve for the transmission tower-line system. The probabilities of failure are evaluated based on two predefined limit states. The results show that the uncertainties from meteorology have considerable influence on the reliability of the transmission tower-line system.
منابع مشابه
Dynamic Responses and Vibration Control of the Transmission Tower-Line System: A State-of-the-Art Review
This paper presented an overview on the dynamic analysis and control of the transmission tower-line system in the past forty years. The challenges and future developing trends in the dynamic analysis and mitigation of the transmission tower-line system under dynamic excitations are also put forward. It also reviews the analytical models and approaches of the transmission tower, transmission lin...
متن کاملمطالعات ساختاری- اقتصادی طرح ارتقای سیستم انتقال 63 کیلوولت دو مداره سراوان – سوران به سطح 230 کیلوولت
Upgrading the voltage level of a transmission line is named as one solution to increase the transmitted power. This paper introduces the results of a research project in which the upgrade of Saravan-Sooran double circuit transmission system from 63 kV to 230 kV is studied. In this context, the towers remain in their current locations, where the new structure of towers and insulators as well as ...
متن کاملThe Effect Analysis of Strain Rate on Power Transmission Tower-Line System under Seismic Excitation
The effect analysis of strain rate on power transmission tower-line system under seismic excitation is studied in this paper. A three-dimensional finite element model of a transmission tower-line system is created based on a real project. Using theoretical analysis and numerical simulation, incremental dynamic analysis of the power transmission tower-line system is conducted to investigate the ...
متن کاملWind-induced Vibration Optimal Control for Long Span Transmission Tower-line System
In this paper, tuned mass dampers with optimal parameters for long span transmission tower-line system are investigated. Equations of motion for a structure-TMD system are derived, and the parameters of TMD, stiffness and damping are optimized, respectively. According to a real project, three-dimensional finite element models of both transmission tower and transmission tower-line system are cre...
متن کاملLightning Performance and its Prevention for Quadruple-circuit Transmission Line with 220kV/110kV Voltage in a Tower
According to the physical process of discharge development of insulator that is struck by lightning, the lightning flashover model for quadruple-circuit transmission line with dual voltage 220kV/110kV in same tower is established basing on EMTP. The actual evaluation index of lightning protection performance is adopted with the consideration of influence of system voltage. The characteristics o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -