Effective dose and energy imparted in diagnostic radiology.

نویسندگان

  • W Huda
  • N A Gkanatsios
چکیده

The patient effective dose, E, is an indicator of the stochastic radiation risk associated with radiographic or fluoroscopic x-ray examinations. Determining effective doses for radiologic examinations by measurement or calculation is generally very difficult. By contrast, the energy imparted, epsilon, to the patient may be obtained from the x-ray exposure-area product incident on the patient. As energy imparted is approximately proportional to the effective dose for any given x-ray radiographic view, the availability of E/epsilon ratios for common radiographic projections provides a convenient way for estimating effective doses. Ratios of E/epsilon were obtained for 68 projections using E and epsilon values obtained from published dosimetry data computed using Monte Carlo techniques on an adult anthropomorphic phantom. The average E/epsilon ratio for the 68 projections in adults was 17.8+/-1.4 mSv/J, whereas uniform whole body irradiation corresponds to 14.1 mSv/J. The major determinant of E/epsilon ratios was the projection employed (the body region irradiated and x-ray beam orientation), whereas the tube potential and beam filtration were of secondary importance. Adult E/epsilon ratios may also be used to obtain effective doses to pediatric patients undergoing x-ray examinations by application of a correction factor based on the patient mass.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of Dose-Area Product compared with three other dosimetric quantities used to estimate patient effective dose in diagnostic radiology

Background: Application of Dose-area product (DAP) quantity has been increased in the clinical practice. DAP is relatively easy to measure. DAP has been shown to correlate well with the total energy imparted to the patient, which is related to the effective dose. Material and Methods: In this study, measurements of DAP were carried out in a sample of 421 adult patients who underwent convention...

متن کامل

Computation of energy imparted in diagnostic radiology.

Energy imparted is a measure of the total ionizing energy deposited in the patient during a radiologic examination and may be used to quantify the patient dose in diagnostic radiology. Values of the energy imparted per unit exposure-area product, omega (z), absorbed by a semi-infinite water phantom with a thickness z, were computed for x-ray spectra with peak x-ray tube voltages ranging from 50...

متن کامل

Measurement of Entrance Skin Dose and Effective Dose in The most Common Diagnostic radiology Examinations in Jiroft, Iran

Introduction: Medical uses of radiation have grown very rapidly over in the past two decades, medical uses represent the largest source of exposure to people, The most important methods in medical diagnosis are the useses of diagnostic radiology exams. Although the use of these methods is very beneficial for the treatment of patients, but ionizing radiation produces ion pairs, ...

متن کامل

Evaluation of the Quality Control Program for Diagnostic Radiography and Fluoroscopy Devices in Syria during 2005-2013

Introduction: Extensive use of diagnostic radiology is the largest contributor to total population radiation doses. Thus, appropriate equipment and safe practice are necessary for good-quality images with optimal doses. This study aimed to perform quality control (QC) audit for radiography and fluoroscopy devices owned by private sector in Syria (2005-2013) to verify compliance of performance o...

متن کامل

Adult patient doses in interventional neuroradiology.

We investigated radiation doses to 149 adult patients who underwent interventional neuroradiologic procedures, consisting of 132 patients who had diagnostic imaging examinations and 17 patients who had therapeutic procedures. The interventional procedures were carried out on a biplane system capable of performing fluoroscopy and digital subtraction angiography (DSA). The x-ray imaging system wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 24 8  شماره 

صفحات  -

تاریخ انتشار 1997