The impact of body mass index on dosimetric quality in low-dose-rate prostate brachytherapy
نویسندگان
چکیده
PURPOSE Low-dose-rate (LDR) brachytherapy has been established as an effective and safe treatment option for men with low and intermediate risk prostate cancer. In this retrospective analysis, we sought to study the effect of body mass index (BMI) on post-implant dosimetric quality. MATERIAL AND METHODS After institutional approval, records of patients with non-metastatic prostate cancer treated in Puerto Rico with LDR brachytherapy during 2008-2013 were reviewed. All patients were implanted with 125I seeds to a prescription dose of 145 Gy. Computed tomography (CT) based dosimetry was performed 1 month after implant. Patients with at least 1 year of prostate-specific antigen (PSA) follow-up were included. Factors predictive of adequate D90 coverage (≥ 140 Gy) were compared via the Pearson χ2 or Wilcoxon rank-sum test as appropriate. RESULTS One-hundred and four patients were included in this study, with 53 (51%) patients having a D90 ≥ 140 Gy. The only factor associated with a dosimetric coverage detriment (D90 < 140 Gy) was BMI ≥ 25 kg/m2 (p = 0.03). Prostate volume (p = 0.26), initial PSA (p = 0.236), age (p = 0.49), hormone use (p = 0.93), percent of cores positive (p = 0.95), risk group (p = 0.24), tumor stage (p = 0.66), and Gleason score (p = 0.61) did not predict D90. CONCLUSIONS In this study we show that BMI is a significant pre-implant predictor of D90 (< 140 Gy vs. ≥ 140 Gy). Although other studies have reported that prostate volume also affects D90, our study did not find this correlation to be statistically significant, likely because all of our patients had a prostate volume < 50 cc. Our study suggests that in patients with higher BMI values, more rigorous peri-implant dosimetric parameters may need to be applied in order to achieve a target D90 > 140 Gy.
منابع مشابه
Determination of Dosimetric Characteristics of IrSeed 125I Brachytherapy Source
Introduction Low dose rate brachytherapy sources have been widely used for interstitial implants in tumor sites, particularly in prostate. Dosimetric characteristics of a new IrSeed 125I brachytherapy source have been determined using the LiF thermoluminescent dosimeter (TLD) chips. Materials and Methods Dose rate constant, radial dose function, and anisotropy function around the IrSeed 125I so...
متن کاملEstimation of dosimetric parameters of I-125 brachytherapy source model 6711 using GATE8.1 code
Brachytherapy is one type of internal radiation therapy where radiation sources, which are usually encapsulated are placed as close as possible to the tumor site inside the patient's body. In this technique, it is important to determine dose distribution around the brachytherapy capsule. Hereby, in this paper, dosimetric parameters of I-125 brachytherapy source model 6711 are estimated accordin...
متن کاملThe investigation of prostatic calcifications using μ-PIXE analysis and their dosimetric effect in low dose rate brachytherapy treatments using Geant4.
Low dose rate brachytherapy is a widely used modality for the treatment of prostate cancer. Most clinical treatment planning systems currently in use approximate all tissue to water, neglecting the existence of inhomogeneities, such as calcifications. The presence of prostatic calcifications may perturb the dose due to the higher photoelectric effect cross section in comparison to water. This s...
متن کاملThe impact of body mass index on the external dose rate from patients treated with radioiodine-131: A preliminary study
Introduction: The relation between patient Body Mass Index (BMI) and the external dose rate of thyroid cancer patients treated with 131I has been investigated. Methods: A total of 183 patients treated with 131I were selected randomly and divided according to their administrated activity into three groups: 3.7GBq, 5.5GBq and 7.4GBq. They were also stratified into three gro...
متن کاملDosimetric Parameters Estimation of I-125 Brachytherapy Source in fat phantom using GATE8.0 code
Introduction: Brachytherapy is one type of internal radiation therapy where radiation sources, which are usually encapsulated, are placed as close as possible to the tumor site or inside the patient's body. In this technique, it is important to determine dose distribution around the brachytherapy capsule to create optimal treatment plant. In this way, dosimetric parameters are...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 8 شماره
صفحات -
تاریخ انتشار 2016