Enhancement of a tuned mass damper for building structures using fuzzy logic

نویسندگان

  • Sanooj Edalath
  • Anant R Kukreti
  • Kelly Cohen
چکیده

Over the past 10 years there has been a growing need to introduce closed-loop control technology for vibration suppression of buildings subject to wind or earthquake disturbances. This paper deals with the investigation of the effectiveness of a fuzzy logic based time variable damping tuned mass damper (TMD) on a building structure undergoing free and forced vibrations. The uniqueness of this approach is the application of a robust, nonlinear fuzzy based controller to emulate a time-optimal control strategy. Fuzzy logic based time variable damping is introduced into a semi-active TMD in order to enhance its performance in the vibration suppression of buildings. First, a single story structure for three different vibration suppression approaches is studied. The fuzzy logic based time variable damping TMD (fuzzy TMD) is compared to the baseline passive TMD as well as a conventional proportional-derivative (PD) controller. Forced vibration is introduced using a resonant harmonic sinusoidal excitation (i.e. same frequency as the fundamental frequency of the structure). Finally, the fuzzy TMD is compared to the baseline for the free vibration of a 15 story structure. For both structures studied, MATLAB based simulation results show that the passive TMD and the PD, both constant gain approaches, provide similar results whereas the fuzzy TMD yields half the settling time. This effort clearly demonstrates the potential of a variable gain (damping) strategy for the vibration suppression of buildings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Tuned Mass Damper on Seismic Response of Building Frames with Uncertain Structural Characteristics

Tuned mass dampers (TMDs) could be used to absorb the input energy of the applied load, and reduce the response of the building frames. However, the effectiveness of TMD in reducing the response of the building frames could be affected by inherited uncertainties in the structural characteristics of the frames. In this study, in order to investigate the probabilistic response of steel moment-res...

متن کامل

Tuned Mass Dampers for Earthquake Vibrations of High-rise Buildings using Bee Colony Optimization Technique

This paper investigates the application of Artificial Bee Colony (ABC) method for the optimization of Tuned Mass Dampers (TMDs) employed for high-rise structures including Soil Structure Interaction (SSI). The model is a 40-story building, and Newmark method is utilized for the structure response to Bam earthquake data. The objective is to decrease both maximum displacement and accelerati...

متن کامل

Optimum Parameters for Tuned Mass Damper Using Shuffled Complex Evolution (SCE) Algorithm

This study is investigated the optimum parameters for a tuned mass damper (TMD) under the seismic excitation. Shuffled complex evolution (SCE) is a meta-heuristic optimization method which is used to find the optimum damping and tuning frequency ratio for a TMD. The efficiency of the TMD is evaluated by decreasing the structural displacement dynamic magnification factor (DDMF) and acceleration ...

متن کامل

Vibration Control of MDOF Structure under Earthquake Excitation using Passive Control and Active Control

In the present paper, active control system is used in different heights of the building and the most effective part was studied where the active control system is applied. The mathematical model of the building is established in MATLAB and in order to active control the system FLC method was used. Three different locations of the building are chosen to apply active control system, namely at th...

متن کامل

AN OPTIMAL CUCKOO SEARCH-FUZZY LOGIC CONTROLLER FOR OPTIMAL STRUCTURAL CONTROL

An optimal semi-active Cuckoo- Fuzzy algorithm is developed to drive the hydraulic semi-active damper for effective control of the dynamic deformation of building structures under earthquake loadings, in this paper. Hydraulic semi-active dampers (MR dampers) are semi active control devices that are managed by sending external voltage supply. A new adaptive fuzzy logic controller (FLC) is introd...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013