Article

structural slenderness effect of tall building in linear & dynamic method

structural slenderness effect of tall building in linear & dynamic method

Download full textFree with an account; signing up with Google takes seconds

Abstract

the structural slenderness ration (height/ with) is one of the title that can be discussed in quake design of building. but unfortunately, in iranian code isn’t mention this mater.in this article, bending and bracying structures system are chosen with slenderness ratio 2 upto 6. (11, 17, 23, 29, 35 stage).all of structure are analysed and designed in linear method, then analysed in unlinear method by elcentro earthquake too. internal forces (average of moment & shear forces in external and internal frames), drift and hinged plastic joint are calculated.in bending system, internal forces are stricken changed in rate of 3 to 6 at linear method. possibility of structural mechanism (collapse) are increased in this rate too.in bracing structure system, drift are increased in steady procedure and structural mechanism isn’t created

Similar items

  • RESPONSE CONTROL PERFORMANCE OF HYBRID MASS DAMPER WITH CONVERTIBLE ACTIVE AND PASSIVE MODES APPLIED TO A SLENDER TALL BUILDING

    Open-access article1999AIJ Journal of Technology and DesignMorimasaWATAKABE, MasanobuTOHDO, OsamuCHIBA, NobuyukiIZUMI

    A hybrid mass damper system with convertible active and passive modes using a hydraulic actuator has been installed to an actual slender tall building with an aspect ratio of eight constructed in Chiba prefecture. Force vibration tests and observation of behaviors against moderat

  • Facade-Integrated Semi-Active Vibration Control for Wind-Excited Super-Slender Tall Buildings

    Open-access article2020IFAC-PapersOnLineYangwenZhang, ThomasSchauer, LaurenzWernicke, WulfWulff

    Nowadays, skyscrapers are getting higher and more slender due to inner-city concentration, which makes the structure more susceptible to dynamic excitations. The design of super-slender skyscrapers is governed primarily by wind excitation. A traditional Tuned Mass Damper (TMD) ha

  • Tall Buildings with Dynamic Facade Under Winds

    Open-access article2020EngineeringFeiDing, AhsanKareem

    Burgeoning growth of tall buildings in urban areas around the world is placing new demands on their performance under winds. This involves selection of the building form that minimizes wind loads and structural topologies that efficiently transfer loads. Current practice is to se

  • Sustainable structure of tall buildings

    Open-access article2008The Structural Design of Tall and Special BuildingsMahjoubElnimeiri, PrairnaGupta

    Abstract Structure by its own nature is sustainable. It is all about doing more with less. Good structural engineering revolves around achieving efficiency and minimization of material. However, thinking will have to be broadened to accommodate the pressing needs of the environme

  • THERMAL STRESS OF STEEL STRUCTURES OF TALL BUILDINGS IN FIRE : Part 1. Computer analysis method of tall structures exposed to compartment fire

    Open-access article1987Journal of Structural and Construction Engineering (Transactions of AIJ)HIDEKIUESUGI, HIROSHIKOIKE

    Development of thermal stress in high rise building structure exposed to fire is localized around fire compartment in which fire occurs. Behavior of thermal stress in local substructure directly exposed to fire is extended to elasto-plastic and creep range though it is limited in

  • Ambient response of a unique performance‐based design tall building with dynamic response modification features

    Open-access article2013The Structural Design of Tall and Special BuildingsMehmetÇelebi, MohHuang, AnthonyShakal, JohnHooper

    SUMMARY A 64‐story, performance‐based design building with reinforced concrete core shear walls and unique dynamic response modification features (tuned liquid sloshing dampers and buckling‐restrained braces) has been instrumented with a monitoring array of 72 channels of acceler