مطالعه تنش‌های اطراف ایمپلنت به روش اجزای محدود در بریج‌های با ساپورت دندان/ایمپلنت در شرایط اتصال سخت و غیرسخت در پروتزهای سمان شونده

Authors

  • آذری, عباس دانشکده دندانپزشکی، دانشگاه علوم پزشکی تهران
  • نیکزاد, سکینه دانشکده دندانپزشکی، دانشگاه علوم پزشکی تهران
  • کاشانی, جمال مهندس مکانیک
Abstract:

Background and Aims: Freestanding fixed partial prosthesis is considered the first choice whenever possible. However, anatomical limitations for implants and other reasons may create situation in which it would be preferable to connect the implants to teeth. A biomechanical dilemma in a tooth/implant-supported system comes from dissimilar mobility. This disparity cause the bridge to function as a cantilever and a series of potential problems such as osseointegration loss, screw loosening arise. The aim of this study was to analyze the tooth-implant supported bridges in rigid/non-rigid connectors in cemented prostheses using finite element stress analysis. Materials and Methods: In this study four three-dimensional models were simulated by use of Solid works software. These models are: 1-RCCP: rigid connector between tooth and implant, 2-NRC CP1: non-rigid connector at mesial side of implant, 3-NRC CP2: non-rigid connector at distal side of second premolar, 4-NRC CP3: non-rigid connector at the middle of pontic, The stress values of four models loaded with vertical forces (150 N) were analyzed. Results: The maximum stress concentration was located at the crestal bone around implant and stress distribution was more balanced around the teeth except in the model of NRCCP2. Stress distribution was imbalanced in non-rigid connection especially in the NRCCP1 model. The presence of non-rigid connector in bridge increases the stress values in suprastructure and transfers to the adjacent structures. Conclusion: The tooth-implant supported prosthesis should be considered as a valuable prosthetic option. It could be suggested that if tooth and implant abutments are to be used together as fixed prostheses supports, rigid connector is the choice because the prosthesis and implant possess the inherent flexibility to accommodate dissimilar mobility characteristics.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

مطالعه تنش های اطراف ایمپلنت به روش اجزای محدود در بریج های با ساپورت دندان/ایمپلنت در شرایط اتصال سخت و غیرسخت در پروتزهای سمان شونده

زمینه و هدف: در بی دندانی ها بریج با ساپورت ایمپلنت انتخاب اول است. اما محدودیت های آناتومیک و سایر موارد احتمالا شرایطی را ایجاب می کند که ترکیب ایمپلنت و دندان استفاده شود. عدم تشابه جابه جایی (mobility) دندان و ایمپلنت باعث ایجاد اهرم یک طرفه می شود که احتمال شکست یا شل شدن قطعات ایمپلنت را دارد. هدف از این مطالعه ارزیابی تنش اطراف ایمپلنت و دندان در یک بریج سه واحدی فک پایین با دو نوع اتصال...

full text

اثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین

Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...

full text

اثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین

Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...

full text

بررسی تأثیر سمانهای مختلف بر توزیع تنش لایه سمان در پروتزهای ثابت متکی بر ایمپلنت به روش اجزای محدود

  بررسی تأثیر سمانهای مختلف بر توزیع تنش لایه سمان در پروتزهای ثابت متکی بر ایمپلنت به روش اجزای محدود         دکتر احسان قاسمی1- دکتر صابر خزاعی2- دکتر فرشاد باجغلی 3- نعیمه نصری4 - دکتر پدرام ایرانمنش 5   1- استادیار، مرکز تحقیقات مواد دندانی، گروه آموزشی پروتزهای‌ دندانی، ‌دانشکده دندانپزشکی، دانشگاه علوم ‌پزشکی اصفهان، اصفهان،ایران   2- دندانپزشک، دانشکده دندانپزشکی، دانشگاه علوم پزشکی کرما...

full text

ارزیابی میزان دقت فریم های حاصل از قالبگیری به روش اسپلینت اجزای پروتزهای با ساپورت ایمپلنت

خلاصه: سابقه و هدف: دندانپزشک می تواند با کنترل و کم کردن میزان خطای حین قالبگیری، خطای ناشی از ساخت فریم ورک های بریج  را کاهش دهد. قالبگیری Open Tray با اسپلینت، روشی است که دقت آن هنوز مورد سوال است، بنابراین هدف از مطالعه حاضر بررسی میزان گپ ایجاد شده در فریم ورک‌های حاصل از قالبگیری مستقیم با و بدون استفاده از اسپلینت اجزا می‌باشد.   مواد و روش ها: این مطالعه تجربی- آزمایشگاهی بر روی دو عد...

full text

ارزیابی میزان دقت فریم های حاصل از قالبگیری به روش اسپلینت اجزای پروتزهای با ساپورت ایمپلنت

خلاصه: سابقه و هدف: دندانپزشک می تواند با کنترل و کم کردن میزان خطای حین قالبگیری، خطای ناشی از ساخت فریم ورک های بریج  را کاهش دهد. قالبگیری open tray با اسپلینت، روشی است که دقت آن هنوز مورد سوال است، بنابراین هدف از مطالعه حاضر بررسی میزان گپ ایجاد شده در فریم ورک های حاصل از قالبگیری مستقیم با و بدون استفاده از اسپلینت اجزا می باشد.   مواد و روش ها: این مطالعه تجربی- آزمایشگاهی بر روی دو عد...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 23  issue None

pages  95- 103

publication date 2010-10

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

No Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023