بررسی میزان همخوانی نتایج اندازه گیری خستگی ذهنی با مقیاس VAS) Visual Analog Scale) و دستگاه Flicker Fusion

نویسندگان

  • فرهادی, مسعود دانشگاه علوم پزشکی شهید صدوقی یزد
  • قریشی, ابوالفضل گروه روانپزشکی، دانشگاه علوم پزشکی زنجان
  • کمالی, کوروش گروه بهداشت عمومی، دانشگاه علوم پزشکی زنجان
چکیده مقاله:

Introduction: Mental fatigue is defined as body or soul tiredness which can be caused by stress, overwork, excessive use of drugs or physical or mental illnesses. Fatigue is one of the reasons of productivity loss as well as occurring accidents. Therefore, mental fatigue measurement is of great importance. This study was aimed to determine the consistency of mental fatigue measurement by self-reported VAS and the flicker fusion apparatus. Material and Methods: A descriptive study was conducted on 30 students. After they had accomplished mental tasks (i.e. mathematical problem solving and responding to MMPI questionnaire), mental fatigued was measured by self-reported VAS and flicker fusion apparatus. To analyze the results, paired sample T-test and Spearman correlation test were applied in SPSS software version 11.5 (P<0.05). Findings: The results of mental fatigue measurements by both methods of self-reported VAS and the flicker fusion apparatus showed significant increase in mental fatigue after finishing each of the mental tasks. But the findings revealed no consistency between the two methods.  Conclusion: Since self-reported VAS is a subjective technique, it seems that the lack of consistency between the two methods is due to its inefficiency in the mental fatigue measurement. Therefore, further studies with more precise methods such as EEG is suggested. Normal 0 false false false EN-US X-NONE FA /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal" mso-tstyle-rowband-size:0 mso-tstyle-colband-size:0 mso-style-noshow:yes mso-style-priority:99 mso-style-parent:"" mso-padding-alt:0cm 5.4pt 0cm 5.4pt mso-para-margin-top:0cm mso-para-margin-right:0cm mso-para-margin-bottom:10.0pt mso-para-margin-left:0cm line-height:115% mso-pagination:widow-orphan font-size:11.0pt font-family:"Calibri","sans-serif" mso-ascii-font-family:Calibri mso-ascii-theme-font:minor-latin mso-hansi-font-family:Calibri mso-hansi-theme-font:minor-latin mso-bidi-font-family:Arial mso-bidi-theme-font:minor-bidi}

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Visual analog scale (VAS) and nasal obstruction in persistent allergic rhinitis.

OBJECTIVE Nasal airflow resistance, as measured by rhinomanometry, is frequently impaired in allergic rhinitis (AR). However, rhinomanometry is scarcely available. The aim of this study was to verify the suitability of the use of visual analog scales (VAS) as a surrogate for rhinomanometry in quantifying nasal obstruction in patients with persistent allergic rhinitis. STUDY DESIGN Prospective...

متن کامل

روایی و پایایی مقیاس پندار ذهنی و مقیاس اصلاح شده کوپر-هارپر در اندازه گیری بار کاری ذهنی

Introduction: High mental workload is one of the important factors that results in errors in safety and occupational health scope and its measurement has high importance. So, this study aimed to determine validity and reliability of Verbal Online Subjective Opinion (VOSO) and Modified Cooper-Harper (MCH) scales in measuring mental workload. Methods: This study was conducted on 90 male studen...

متن کامل

Visual experience can substantially alter critical flicker fusion thresholds.

Studies of psychopharmacology often use the test of the critical flicker fusion (CFF) threshold as a measure of total information processing. It is true that studies of practice effects have shown that CFF thresholds are remarkably stable within and across multiple days of testing. This study confirms that subjects who undergo CFF testing on sequential days have stable thresholds, but also demo...

متن کامل

Enhancements to the Visual Analogue Scale, VAS, for listening tests

Three methods for perceptual rating of audio stimuli were compared. The Visual Analogue Scale, VAS, was implemented as two computer programs and compared to the VAS on paper. The first program is a straight-forward implementation, the second program introduces the Visual Sort and Rate method, VSR. VSR allows the subject to compare stimuli of similar rating to each other, thus making the orderin...

متن کامل

بررسی میزان همخوانی نتایج راهبردهای مختلف ارزشیابی تدریس استادان

این پژوهش با هدف تعیین میزان همخوانی نتایج راهبردهای مختلف ارزشیابی از تدریس استادان پژوهشی از نوع توصیفی- همبستگی انجام گرفت. جامعه آماری تحقیق دانشجویان، دانش‌آموختگان و اعضای هیئت علمی دانشکده ادبیات و علوم انسانی دانشگاه کردستان در سال 1391 بودند. ابزار پژوهش، پرسشنامه اقتباس شده از کاربرگ‌های وزارت علوم، تحقیقات و فناوری بود. پایایی پرسشنامه‌ها با استفاده از آزمون آلفای کرونباخ تأیید شد. ب...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 1  شماره 1

صفحات  66- 72

تاریخ انتشار 2013-09

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023