A Comparison between Different Editions of API650 Seismic Provisions for Cylindrical Steel Storage Tanks Considering the Fragility Curves

نویسنده

  • Hooman Fili Ph.D.Student,Qazvin Branch, Islamic Azad University, Qazvin, Iran
چکیده مقاله:

Seismic safety of liquid storage tanks is of considerable importance due to its application in different industries. In Iran, most of these storage tanks are designed based on API650 code provisions. Despite designing tanks according to API standard, the lesson learned from previous earthquakes, shows different kind of damage occurring on them. This study is an investigation on evaluating different revisions of API650 seismic codes from years 2001 to 2013. The failure modes considered are Buckling, Overturning, Sliding and Shell Yielding. For this, three steel cylindrical tanks has been checked by different revisions of API650 under different PGA from 0.1 to 2 and various failure modes are taken into account respectively for each tank. According to these information, the fragility curves are derived and compared among all the revisions of API650 code. According to the resultsit seems that API650 in edition of 2001, Presents buckling criteria as the main criterion.This criterioncompared to the overturning criteria even in unanchored tanks­determinedvery conservative.In these samplesthere were no overturning criteria prior. In 2005, 2009 and 2013 editions of API650 for unanchored tanks, presented overturning criteria as the main criterion considering the sliding and total stress failure criteria but for anchored tanks total stress failure criteria controlled much more conservatively. Generally buckling criteria not reported in prior.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison of Seismic Safety of Steel MRF Designed According to Different Editions of Iranian Seismic Code

In this paper, efforts are made to compare the safety of steel moment resistant frames designed according to different editions of the Iranian code of Practice for seismic resistant design of buildings. Also, failure risk of a low and medium height frame which designed for high and low seismicity regions according to three editions of the code are evaluated. First, the testing cases were design...

متن کامل

Seismic fragility assessment of RC moment resisting frame buildings designed for different editions of Iranian seismic design code

Background and objective: Developing fragility and vulnerability functions are important tools in seismic reliability assessment of buildings and are widely used in regional seismic risk studies. To date sufficient studies for developing analytical fragility functions for Iranian code-conforming buildings have not been carried out. Performing such studies are necessary to assess the adequacy of...

متن کامل

A methodology for Determining the Seismic Vulnerability of Old Concrete Highway Bridges by Using Fragility Curves

Past earthquakes have demonstrated that old RC bridges may be seismically vulnerable. Bridge responses during the last decades illustrated the necessity of the seismic assessment of bridges especially those which were designed with old codes. In this research an existing concrete bridge representative of the most common bridges in the highway system in Iran are studied. Push over and nonlinear ...

متن کامل

Improving seismic performance of elevated cylindrical water storage tanks using nonlinear isolators incorporating liquid–structure interaction

Pervasive construction of elevated liquid tanks as the most important sources for urban hygienic water, and their failure under earthquake, highlighs the necessity for research toward new passive control devices. Design and use of base-isolation systems for elevated liquid tanks is propounded as a novel seismic engineering technology. To date, no special examination has been discussed in relati...

متن کامل

Study on the dynamic behavior of cylindrical steel liquid storage tanks using finite element method

Dynamic behavior of ground supported cylindrical storage tanks (CST) is of crucial importance because of its applications in industrial complexes. Seismic behavior of tanks is greatly affected by the height to diameter ratio, fluid height and fluid type. Five CSTs with different height to diameter ratios, three CSTs with the same height and diameters but various fluid heights and one CST with t...

متن کامل

Introduction of Air Cushion to Reduce Seismic Demand in Cylindrical Water Storage Tanks

Water storage tanks not designed explicitly for seismic loading could require retrofit. One of the common ways of retrofit include some structural change in the lateral load resisting system that could be expensive and requires the tank to be out of service for relatively long time. This paper introduces a novel method to reduce seismic demand on tank’s wall without structural intervention. Thi...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 4  شماره 3

صفحات  37- 50

تاریخ انتشار 2014-09-30

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023