A New Method to Enhance the Low Voltage Ride Through Capability of Doubly Fed Induction Generator Using Resistive Type Superconducting Fault Current Limiter

نویسندگان

چکیده مقاله:

In the event of voltage sag at the nearing of a wind park, severe currents may pass through the power electronic devices of the Doubly Fed Induction Generators (DFIGs). Hence, according to the Low Voltage Ride Through (LVRT) requirements, the wind parks are allowed to disconnect from the network after a certain time. Therefore, to avoid such actions, the LVRT requirement of wind parks is considered to be enhanced in this paper. This aim is achieved by offering a novel objective function in order to find the optimum impedance of Superconducting Fault Current Limiter (SFCL). To evaluate the effectiveness of the proposed method, it is verified in MATLAB/SIMULINK and its great performance to amend the LVRT of such wind parks is corroborated by the simulation results.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low Voltage Ride-Through Capability Improvement of Doubly Fed Induction Generator using DVR and SMES

Abstract: With the growth of communities and the increasing need for electricity, and because of the many benefits of renewable energy sources, the wind turbine has become a completely commercial and inevitable process, with increasing penetration into the electricity grid. Distribution networks, on the other hand, are subject to fault that cause power fluctuations and outflow of wind units. In...

متن کامل

Improvement of Low Voltage Ride – through Capability of Distributed Generation in a Microgrid Using Superconducting Fault Current Limiter

Although the introduction of distributed generation (DG) in a distribution system improves the power quality of power system, it increases the fault current level reducing voltage at point of common-coupling (PCC). Hence, there is a need of improving fault ride-through (FRT) capability to avoid sudden tripping of DG units from the utility grid during voltage sag in a faulty condition. In this p...

متن کامل

Proportional-Resonant Control of Doubly-Fed Induction Generator Wind Turbines for Low-Voltage Ride-Through Enhancement

A novel control strategy is proposed in this paper for the rotor side converter (RSC) of doubly-fed induction generator (DFIG)-based wind power generation systems. It is supposed to enhance the low-voltage ride-through (LVRT) capability of DFIGs during great-level grid voltage dips. The strategy consists of a proportional-resonant (PR) controller and auxiliary PR controllers. The auxiliary cont...

متن کامل

Low voltage ride through of doubly-fed induction generator connected to the grid using sliding mode control strategy

Wind Energy Conversion System (WECS) based on Doubly Fed Induction Generator (DFIG) connected to the grid is subjected to high transient currents at rotor side and rise in DC-link voltage during voltage sag at stator/grid side. To secure power system operation wind turbines have to meet grid requirements through the Low voltage ride through (LVRT) capability and contribute to grid voltage contr...

متن کامل

High Voltage Ride Through with FACTS for Wind Turbines with Doubly Fed Induction Generator

In future grid codes wind farms will have to fulfill demanding fault ride through requirements. Among several grid faults the voltage swell is a critical event. Wind farms with doubly-fed induction generators will not be able to fulfill the new grid code requirements without additional fault mitigation equipment. In this publication the applicability of the Dynamic Voltage Restorer and the Stat...

متن کامل

Study on the Low Voltage Ride-Through of Doubly-Fed Induction Generator Based on BP Neural Network

In order to ensure that wind turbines could be online under the condition of power grid transient fault, the technology of low voltage ride-through (LVRT) for wind turbine has become a research focus of experts and scholars at home and abroad. In current wind turbine control strategy, the PI parameters of the control system keep unchanged when the wind turbine is in the process of LVRT, which a...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 19  شماره JIAEEE Vol.19 No.4

صفحات  153- 162

تاریخ انتشار 2022-09

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023