Assessment and evaluation of patient doses in adult common CT examinations towards establishing national diagnostic reference levels

نویسندگان

  • H.R. Khosravi Nuclear Sciences School, Nuclear Science and Technology Research Institute, and Nuclear & Radiation Support Department, Iranian Nuclear Regulatory Authority, Tehran, Iran
  • L. Sadri Department of Nuclear Engineering and Physics, Amir Kabir University of Technology, Tehran, Iran
  • S. Setayeshi Department of Nuclear Engineering and Physics, Amir Kabir University of Technology, Tehran, Iran
چکیده مقاله:

Background: Patient radiation doses from computed tomography (CT) are increasing due to the number of CT examinations performed every day. The aim of this study was assess and evaluate patient radiation doses for adult’s common CT examinations to derive local diagnostic guidance levels for common CT examinations. Materials and Methods: Volume and weighted computed tomography dose index (CTDIvol,w) and dose length product (DLP) of four common CT examinations including head, head sinus, chest, abdomen and pelvis were measured for 8 different CT scanners using standard head and body phantoms. The image quality of acquired scan images were assessed according to European Commission (EC) image quality criteria guidelines. Results: The mean measured CTDIw for head base head cerebrum, head sinus, chest and abdomen-pelvis were 71.8, 29.7, 35.8, 9.8 and 12.9 mGy, respectively. The DLP for head, head sinus, chest and abdomen-pelvis were 500, 371, 225 and 482 mGy.cm. The results of our study were shown more patient doses in terms of DLP for head sinus in compare with other studies while CTDIw values for head base and sinus were higher than EC measurements. Conclusion: The great variations of CTDIw and DLP observed among hospitals and relatively high values of DLP in some centers are evidence that radiation doses of patients from CT examinations is not fully optimized. It was concluded that future studies of continues optimization to minimize the dose without affecting image quality are needed.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

assessment and evaluation of patient doses in adult common ct examinations towards establishing national diagnostic reference levels

background: patient radiation doses from computed tomography (ct) are increasing due to the number of ct examinations performed every day. the aim of this study was assess and evaluate patient radiation doses for adult’s common ct examinations to derive local diagnostic guidance levels for common ct examinations. materials and methods: volume and weighted computed tomography dose index (ctdivol...

متن کامل

Patient doses in CT examinations in Switzerland: implementation of national diagnostic reference levels.

Diagnostic reference levels (DRLs) were established for 21 indication-based CT examinations for adults in Switzerland. One hundred and seventy-nine of 225 computed tomography (CT) scanners operated in hospitals and private radiology institutes were audited on-site and patient doses were collected. For each CT scanner, a correction factor was calculated expressing the deviation of the measured w...

متن کامل

Local Diagnostic Reference Levels for Some Common Diagnostic X-Ray Examinations In Sabzevar County of Iran

Introduction: Diagnostic reference level (DRL) is a useful tool for the promotion of optimization. The national DRLs (NDRLs) are useful, brief, and robust guidelines for optimizing radiation protection in a country. The aim of this study was to extract the local DRLs (LDRLs) for some common radiologic examination in Sabzevar county. Materials and Methods: There are eight radiology departments ...

متن کامل

Evaluation of dose‐area product of common radiographic examinations towards establishing a preliminary diagnostic reference levels (PDRLs) in Southwestern Nigeria

In Nigeria, a large number of radiographic examinations are conducted yearly for various diagnostic purposes. However, most examinations carried out do not have records of doses received by the patients, and the employed exposure parameters used are not documented; therefore, adequate radiation dose management is hin-dered. The aim of the present study was to estimate the dose-area product (DAP...

متن کامل

Paediatric Dose AssessmentToward Establishment of National Diagnostic Reference Levels for Digital Radiography Examinations in Iran

Introduction: Paediatric patients deserve special attention because of the higher radiation risks compared with adults. The main purpose of this study is to determine patient dose and diagnostic reference level for Paediatric through Entrance Surface Dose (ESD) calculations in common X-ray examination and to establish Paediatric national DRLs in digital radiography in Iran. <...

متن کامل

Diagnostic reference levels at intraoral and dental panoramic examinations

Background: The aim of this study was to measure and determine diagnostic reference levels (DRLs) of programs used at intraoral and dent panoramic examinations in Kosovo. Materials and Methods: To determine DRL, were performed measurements for dose area product (DAP) at intraoral and dental panoramic radiology systems. This study has covered over 47% of X-ray units, which are in use for intraor...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 11  شماره None

صفحات  245- 252

تاریخ انتشار 2013-10

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023