Characteristics of lead glass for radiation protection purposes: A Monte Carlo study

نویسندگان

  • C. Olaru Horia Hulubei National Institute for Research and Development in Physics and Nuclear Engineering, Bucharest-Magurele, Romania
  • G.V. Ormenisan Horia Hulubei National Institute for Research and Development in Physics and Nuclear Engineering, Bucharest-Magurele, Romania
  • M. Zadehrafi Horia Hulubei National Institute for Research and Development in Physics and Nuclear Engineering, Bucharest-Magurele, Romania
  • S.A. Ciobanu Horia Hulubei National Institute for Research and Development in Physics and Nuclear Engineering, Bucharest-Magurele, Romania
چکیده مقاله:

Background: Lead glass has a wide variety of applications in radiation protection. This study aims to investigate some characteristics of lead glass such as the γ-ray energy-dependent mass and linear attenuation coefficients, the half-value layer thickness, and the absorbed dose distribution for specific energy. Materials and Methods: The attenuation parameters of different lead glass types against high-energy photons (0.2-3 MeV) of gamma rays have been calculated by the Monte Carlo technique and a deterministic method. Besides, the depth dose distribution inside the volume of two cubic lead glass samples was calculated by two Monte Carlo-based computer codes, for gamma rays of 300 keV. In each part of the study, the results of the two methods have been compared. Results: Increasing the Pb concentration (weight in %) by 1% in the lead glass causes a 1.6%-3% increase in the linear attenuation coefficient, depending on the energy. However, the mass attenuation coefficient does not show significant variation for different types of lead glass, especially for the energies higher than 400 keV. Moreover, almost half of the total dose from 300 keV photons will be absorbed in the first 3.5 mm of the sample’s thickness. Conclusion: Results indicate that the Monte Carlo technique is as reliable as the deterministic methods for calculating the attenuation characteristics of the lead glass. The provided data in this investigation can be useful for radiation protection purposes, especially in the case of selecting the lead glass type and dimension based on a specific application.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation putty metal as internal shield for patient protection of electron therapy by Monte Carlo study

Introduction: In this study, a specific combination (70% W 18.61% Ni and 11.39% C) of lead free and flexible putty metal is introduced and validated as internal shielding by Mont Carlo study Materials and Methods: To evaluate putty metal as an internal shielding by Mont Carlo study Varian 2100 C/D was validated within measurement and then by given energy spect...

متن کامل

Assessment of the Radiation Attenuation Properties of Several Lead Free Composites by Monte Carlo Simulation

Background:In diagnostic radiology lead apron, are usually used to protect patients and radiology staff against ionizing radiation. Lead apron is a desirable shield due to high absorption and effective attenuation of x-ray photons in the diagnostic radiology range.Objective: Although lead aprons have good radiation protection properties, in recent years, researchers have been looking for altern...

متن کامل

Monte Carlo study of a vortex glass model

We describe results of Monte Carlo simulations on a model that seems to have the necessary ingredients to describe a disordered type-II superconductor in a magnetic field. We compute the free energy cost to twist the direction of the phase of the condensate and analyze the results by finite-size scaling. The results show convincingly that the model has different behavior as a function of dimens...

متن کامل

Monte Carlo Studies for the Design of a Lead Glass Drift Calorimeter

A drift collection calorimeter having a combined radiator and field shaping structure made of lead glass tubing is described. With the aid of the EGS Monte Carlo code we show that such a device, when pressurized to 10 atmospheres, will give a resolution of a/E = 9.6%/E1j2 provided that the shower is contained at a 99% level. Track length restriction and Landau sampling have been included in the...

متن کامل

A Monte Carlo simulation study on the effectiveness of electron filters designed for telecobalt radiation therapy treatment

Background: The aim of present study was to analyze the effectiveness of electron filters in the Telecobalt radiotherapy treatment by simulation technique.  Materials and Methods: The BEAMnrc Monte Carlo code was used to simulate the electron filters of thickness of 0.5 gm/cm2 below the trimmer bar for 35 × 35 cm2 field size in Theratron Equinox-80 telecobalt unit. The electron filters were mad...

متن کامل

A Monte Carlo study of SPECT in boron neutron capture therapy for a heterogeneous human phantom

Background: Boron neutron capture therapy (BNCT) is a binary radiotherapy combining biochemical targeting with neutron irradiation. However, monitoring the boron distribution is a fundamental problem in BNCT. Prompt gamma rays emitted by boron capture reaction can be used to address the issue. Materials and Methods: The general-purpose Monte Carlo toolkits Geant4 and MCNP were used for the simu...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 18  شماره 4

صفحات  907- 912

تاریخ انتشار 2020-10

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023