Comparing the Effect of Reamed Exchange Nailing and Augmentation Compression Plating in Treatment of Femoral Shaft Nonunion

نویسندگان

  • Javadi, Reyhaneh Medical Student, Student Research Committee, Mazandaran University of Medical Sciences, Sari, Iran
  • Ghaffari, Salman Associate Professor, Orthopedic Research Center, Mazandaran University of Medical Sciences, Sari, Iran
  • Shayestehazar, Masoud Associate Professor, Orthopedic Research Center, Mazandaran University of Medical Sciences, Sari, Iran
  • Talebi, Shahin Assistant Professor, Orthopedic Research Center, Mazandaran University of Medical Sciences, Sari, Iran
چکیده مقاله:

 Background and purpose: One of the most important complications of bone fractures is nonunion. This research aimed at comparing the effect of exchange nailing and plate augmentation on complications after surgery and the time to achieve desired outcomes. Materials and methods: This descriptive-analytical study was conducted in 12 femoral shaft nonunion cases treated operatively in 2011-2018 (eight patients were managed with plate augmentation and four patients were treated with exchange nailing). Demographic characteristics of the patients, type of fracture and type of surgery were recorded. A year after the surgery, anteroposterior and lateral view profiles were prepared from all patients and the extent of bone fusion was evaluated by orthopedic surgen. Results: Four patients (33.33%) underwent intraosseous nail replacement surgery and eight (66.67%) underwent plate augmentation surgery. Two patients (16.67%) developed infections and five (41.67%) had a short limb complication. The average limb shortness in these patients was 1.10±0.22 cm. The average duration of union after discharge was lower in patients with plate augmentation than those with replacement of the intramedullary nail. Conclusion: In current study, faster uninon achieved, so, augmentation plating could be a good choice in patients with femoral shaft nonunion.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Augmentative compression plating versus exchanging reamed nailing for nonunion of femoral shaft fracture after intramedullary nailing : A retrospective cohort study.

Aim of the present study was to compare the outcomes between exchanging reamed nailing (ERN) and augmentative compression plating (ACP) in treatment of femoral shaft nonunion after intra-medullary nailing (IMN) retrospectively. A retrospective, multicentre study was performed with 188 patients (190 cases)with femoral shaft nonunion after IMN, who received therapy with either ERN (n = 92) for 44...

متن کامل

Reamed intramedullary exchange nailing: treatment of choice of aseptic femoral shaft nonunion

BACKGROUND The aim of this study was to evaluate a standardized method of treatment of femoral nonunion of the isthmal femur excluding non-united metaphyseal fractures. METHODS Between 2003 and 2010, 72 consecutive patients with nonunion of the femoral shaft were operated using a standardized protocol in our trauma department and followed up for successful union and functional result. RESUL...

متن کامل

Effectiveness of plate augmentation for femoral shaft nonunion after nailing.

BACKGROUND Treatment options for nonunion of the femoral shaft fracture after intramedullary nail fixation are controversial. The methods of exchanging an existing nail with a larger-sized nail, dynamization, removal of the nail followed by plating, and bone grafting have all been reported. From those options, exchange nailing seems to be the most popular choice. In our study, we used plate aug...

متن کامل

Aseptic nonunion of a femoral shaft treated using exchange nailing.

BACKGROUND There are many methods for treating femoral shaft aseptic nonunions of which exchange nailing is the simplest technique. However, the reported success rate varies. Therefore, a prospective study was conducted to further clarify the role of exchange nailing. METHODS From October 1994 through December 1999, 40 femoral shaft aseptic nonunions in 39 patients were treated using exchange...

متن کامل

Comparing Entry Points for Antegrade Nailing of Femoral Shaft Fractures.

The optimal entry point for antegrade intramedullary nailing of femoral shaft fractures remains controversial. The purpose of this systematic review was to determine whether there is a difference in operative parameters, healing, and functional outcome when comparing the greater trochanter (GT) and piriformis fossa (PF) entry points. A systematic search of multiple databases and 3 major orthope...

متن کامل

Exchange nailing for non-union of femoral shaft fractures.

BACKGROUND There are many ways to treat aseptic non-union of femoral shaft fractures with reported varied success rate. Amongst all these, Exchange nailing is the simplest and most successful technique for treating aseptic non union of femoral shaft fractures. We have carried out a prospective study in the Department of Trauma & Orthopaedics, Ayub Medical College Abbottabad to analyse the role ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 31  شماره 192

صفحات  145- 150

تاریخ انتشار 2021-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023