Comparison of the Diagnostic Values of Four-Point and Two-point Ultrasound Versus CT Scan in Determining Pneumothorax

نویسندگان

  • Farsi, Davood Associate Professor, Emergency Medicine, Iran University of medical science, Tehran, Iran
  • Abbasi, Saieed Associate Professor, Emergency Medicine, Iran University of medical science, Tehran, Iran
  • Hessam, Roxana Emergency Medicine Specialist, Iran University of Medical Science, Tehran, Iran
  • Navkhasi, Sasan Department of Medical Surgical Nursing, Asadabad School of Medical Sciences, Asadabad, Iran
  • Saifpanahi, Jamshid Department of Nursing, Kowsar Hospital, Kurdistan University of Medical Sciences, Sanandaj, Iran
  • Zohri, Darab Emergency Medicine Specialist, Iran University of Medical Science, Tehran, Iran
چکیده مقاله:

Background and Objectives: Pneumothorax is a life-threatening complication and the most common cause of which is trauma. Early diagnosis and treatment of Pneumothorax are very important. The aim of this study was to compare the diagnostic values of four-point and double-point ultrasound versus CT scan in determining pneumothorax in Rasul-Akram and Hafte-Tir Hospitals during the years 2015 - 2016. Materials and Methods: This cross-sectional study was performed on 880 trauma patients that selected randomly from the emergency department. The study information was completed based on two-point US and four-point US and the patients’ file records. CT scan, as the gold standard for the diagnosis of pneumothorax, was used for all patients. The crosstab test was used for evaluating the accuracy of two methods and to determine the Kappa coefficient level of agreement. Data were analyzed using SPSS v.16 software. Results: The sensitivity of ultrasonography in the diagnosis of pneumothorax in the two-point technique group was 91.1%, with a specificity of 100%, a positive predictive value of 100% and a negative predictive value of 97.7%. The accuracy in this method was 95.5%. In the four-point technique, the sensitivity was 98.9%, with a specificity of 100%, a positive predictive value of 100% and a negative predictive value of 99.7%. The accuracy in this method was 99.4%. Conclusions: The four-point chest ultrasound is a high accuracy method for the bedside diagnosis of pneumothorax in patients with trauma.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnosis of Pneumothorax by Focused Assessment Sonography of Trauma(eFAST) and CT scan in Chest Trauma: Comparison of diagnostic accuracy

Abstract Aims and objectives: Pneumothorax is a common finding after trauma and with a wide range of clinical manifestations, from a concealed pneumothorax detectable only by a CT scan accidentally, to a potentially fatal tension pneumothorax. Pneumothorax can gradually progress to tension pneumothorax and become an emergency, consequently, a timely diagnosis is essential. Most traumatic patie...

متن کامل

a synchronic and diachronic approach to the change route of address terms in the two recent centuries of persian language

terms of address as an important linguistics items provide valuable information about the interlocutors, their relationship and their circumstances. this study was done to investigate the change route of persian address terms in the two recent centuries including three historical periods of qajar, pahlavi and after the islamic revolution. data were extracted from a corpus consisting 24 novels w...

15 صفحه اول

Comparison of One-point and Two-point Methods for Estimation of Infiltration Parameters in Furrow Irrigation

Infiltration is one of the most important hydraulic parameters affecting surface irrigation and one ofthe most difficult parameters in practical field determinations. The infiltration equations are used todescribe water flow hydraulics and surface irrigation systems design. But determination of theparameters in these equations are costly and time consuming. Therefore, some estimating methods ar...

متن کامل

comparison of catalytic activity of heteropoly compounds in the synthesis of bis(indolyl)alkanes.

heteropoly acids (hpa) and their salts have advantages as catalysts which make them both economically and environmentally attractive, strong br?nsted acidity, exhibiting fast reversible multi-electron redox transformations under rather mild conditions, very high solubility in polar solvents, fairly high thermal stability in the solid states, and efficient oxidizing ability, so that they are imp...

15 صفحه اول

a case study of the two translators of the holy quran: tahereh saffarzadeh and laleh bakhtiar

بطورکلی، کتاب های مقدسی همچون قران کریم را خوانندگان میتوان مطابق با پیش زمینه های مختلفی که درند درک کنند. محقق تلاش کرده نقش پیش زمینه اجتماعی-فرهنگی را روی ایدئولوژی های مترجمین زن و در نتیجه تاثیراتش را روی خواندن و ترجمه آیات قرآن کریم بررسی کند و ببیند که آیا تفاوت های واژگانی عمده ای میان این مترجمین وجود دارد یا نه. به این منظور، ترجمه 24 آیه از آیات قرآن کریم مورد بررسی مقایسه ای قرار ...

15 صفحه اول

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 17  شماره None

صفحات  8- 13

تاریخ انتشار 2019-08

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023