Cr (VI)/Cr (III) SPECIATION BY IN SITU ELECTRODEPOSITION ONTO TUBE PRIOR TO ELECTROTHERMAL ATOMIC ABSORPTION SPECTROMETRY

نویسندگان: ثبت نشده
چکیده مقاله:

این مقاله چکیده ندارد

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preconcentration of gallium by coprecipitation with synthetic zeolites prior to determination by electrothermal atomic absorption spectrometry.

Synthetic zeolites were dissolved in nitric acid, and the resulting solution used as a coprecipitant for the preconcentration of trace amounts of gallium in water samples prior to determination by electrothermal atomic absorption spectrometry (ETAAS). The gallium preconcentration conditions and the ETAAS measurement conditions were optimized. Gallium was quantitatively concentrated with the zeo...

متن کامل

Quantification of vanadium in serum by electrothermal atomic absorption spectrometry.

We describe an ultrasensitive and reliable method for determining vanadium in human serum by electrothermal atomic absorption spectrometry. After lyophilization, the serum is digested in acid at high pressure, and the digests are evaporated to a small volume. Vanadium in the digests is complexed with cupferron, extracted, and dried. The residue is redissolved in formic acid, where it is 15-fold...

متن کامل

Determination of cadmium in wine by electrothermal atomic absorption spectrometry.

A method is described for direct electrothermal atomic absorption spectrometric (ETAAS) determination of cadmium in untreated samples of wine. Pyrolytic graphite tubes and graphite tubes with standard L'vov pyrolytic platforms were tested as atomizers. The detection limit achieved was 0.08 microg L(-1) Cd in wine. The relative standard deviation for the concentration range from 0.2 to 10 microg...

متن کامل

Determination of lead and cadmium in water samples by cloud point extraction prior to flame atomic absorption spectrometry determination

Pb and Cd in water samples were determined by cloud point extraction (CPE) with sodiumdiethyldithiocarbamate (DDTC) as the chelating agent and octylphenoxypolyethanl (Triton X-114) asthe surfactant prior to flame atomic absorption spectrometry (FAAS) determination. The main factorsof affecting the extraction and detection processes were optimized. The preconcentration of 10 mL ofstandard soluti...

متن کامل

Elimination of Chemical and Spectral Interferences in Measurement of Trace Elements in Urine and Blood by Combined Electrodeposition-Electrothermal Atomic Absorption Spectrometry

A combined electrodeposition-ETAAS technique has been applied to the analysis of Pb, Cd, Co, Ni, Cr and Mn in biological samples in order to overcome interferences and to minimize sample pretreatment. It requires minimal sample preparation with the electrolysis process aiding partial decomposition of the organic matrix, adequate for the release and deposition of trace elements. In an initia...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 13  شماره 2

صفحات  -

تاریخ انتشار 2002-06-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023