Design of Small Animal Computed Tomography Imaging for in vitro and in vivo Studies

نویسندگان

  • Ali Reza Kamali-Asl Radiation Medicine Engineering Department, Shahid Beheshti University, GC, Tehran, Iran
  • Farough Mohammad Mamashi Radiation Medicine Engineering Department, Shahid Beheshti University, GC, Tehran, Iran
  • Habib Zaidi Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, 9700 RB Groningen, Netherlands Department of Nuclear Medicine, University of Southern Denmark, 500 Odense, Denmark
  • Hamid Reza Hemmati Radiation Medicine Engineering Department, Shahid Beheshti University, GC, Tehran, Iran
  • Hosein Arabi Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211, Geneva, Switzerland
  • Vahid Lohrabian Radiation Medicine Engineering Department, Shahid Beheshti University, GC, Tehran, Iran
چکیده مقاله:

Introduction: Mini Computed Tomography (mini-CT) was suggested in biomedical research to investigate tissues and small animals. We present designed and built a mini x-ray computed tomography (mini-CT) for small animals as well as industrial component imaging. Materials and Methods: The system used in this study includes a X-ray tube 20kV to 160kV and a flat panel detector with a pixel size of 200µm×200µm. The tested specimens are stacked on a stable rotating system. Due to the ability to change the distance between tube and sample, as well as sample to detector, we can virtually control magnification and FOV. A magnification change will produce images with different spatial resolution. In this way, changing the FOV scanner can actually achieve different spatial resolutions Results: In this scanner, the spatial resolution varies as a function of the system FOV where the FOV can be changed from 43 to 10 (by changing the source to object distance), thus improving the spatial resolution from 3.9 up to 14.4 cycle/mm, respectively. Conclusion: The system designed in this research can be used as a scanner in pre-clinical and industrial research, due to the relationship between the FOV and the spatial resolution.          

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

simulation and experimental studies for prediction mineral scale formation in oil field during mixing of injection and formation water

abstract: mineral scaling in oil and gas production equipment is one of the most important problem that occurs while water injection and it has been recognized to be a major operational problem. the incompatibility between injected and formation waters may result in inorganic scale precipitation in the equipment and reservoir and then reduction of oil production rate and water injection rate. ...

investigating the integration of translation technologies into translation programs in iranian universities: basis for a syllabus design in translation technology

today, information technology and computers are indispensable tools of any profession and translation technologies have become an indispensable part of translator’s workstation. with the increasing demands for high productivity and speed as well as consistency and with the rise of new demands for translation and localization, it is necessary for translators to be familiar with market demands an...

Correlation Between Tissue Densities in Computed Tomography and Three Different Cone-Beam Computed Tomography Units (In Vitro)

Background and Aim: Bone density is of great assistance in the selection of the proper implant site. The present study aimed to assess the correlation between tissue densities in computed tomography (CT) and three different cone-beam computed tomography (CBCT) units. Materials and Methods: In this descriptive study, a radiographic phantom consisting of a transparent polymethyl methacrylate (PM...

متن کامل

Small Animal X-ray Computed Tomography

X-ray computed tomography (CT) systems with high resolution (also known as micro-CT systems) have been developed over the last two decades and have been used with great success in small animal studies. A micro-CT scanner is based on the same underlying physical principle as a clinical CT scanner, but it is designed for higher-resolution imaging. It produces three-dimensional (3D) tomographic da...

متن کامل

Small-animal imaging using clinical positron emission tomography/computed tomography and super-resolution.

Considering the high cost of dedicated small-animal positron emission tomography/computed tomography (PET/CT), an acceptable alternative in many situations might be clinical PET/CT. However, spatial resolution and image quality are of concern. The utility of clinical PET/CT for small-animal research and image quality improvements from super-resolution (spatial subsampling) were investigated. Na...

متن کامل

Artifacts of Titanium, Zirconium, and Binary Titanium-Zirconium Abutments in Compute Tomography, Cone Beam Computed Tomography, and Magnetic Resonance Imaging

Aim: The aim of this in vitro study was to evaluate imaging artifacts induced by Titanium, Zirconium, Titanium-Zirconium abutments in CT, MRI and CBCT imaging modalities.Methods: A 4×8mm titanium fixture was inserted in a dry human mandible. Titanium, Zirconium and Titanium–Zirconium abutments measuring 10.5 mm in height are located on the fixture, one by one. Each abutment was scan...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  401- 401

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023