Determination of internal absorbed dose from radiation of 111In-Rituximab in body

نویسندگان

  • Zahra Mohamad Darvishi MSc Student, Department of Physic, Eslamic Azad University, Tehran, Iran. Author’s
چکیده مقاله:

Introduction: There are many ways to treat cancer and pain relief. One of the methods is radiopharmaceutical therapy. Indium 111-rituximab contains the radioisotope indium-111 and rituximab. The Indium-111, after decay, emits gamma rays with energies of 245 KeV and 171 KeV, and beta-radiation of 26 KeV. In this study, the absorbed dose of 111In-Rituximab in human body was calculated using mice data and MCNPX simulation code for the organs of heart, lung, liver, spleen, kidney, stomach, intestine and pancreas.   Materials and Methods: Male phantom was used for this simulation. The source and target organs were defined in code and absorbed dose obtained for per particle with error of 5 percent. The source organs were determined as volume source in SDEF card of MCNP code. Simulations were done in two steps for gamma and beta sources and the final absorbed dose of each organ were multiplied by the amount of cumulated activity of 1MBq.   Results: The results showed that the absorbed dose due to injection of 111In-Rituximab for organs of spleen and stomach are 2.2252E-02, 5.5979E-03 respectively. so these organs are at risk in treating cancer with this radionuclide. The errors for were less than 5 percent. Conclusion: Monte Carlo method and MCNPX simulation code are important methods for calculation of the absorbed dose after the distribution of rradionuclides in the body. Also the results show that two organs spleen and stomach are at risk in Indium 111-rituximab therapy.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment the Effect of Kidney Internal Structure on Gamma Absorbed Dose of Radiopharmaceutical 111In-DTPA

Large quantities of radiopharmaceuticals prescribed for treatment and diagnosis are excreted through kidney. Therefore, radiation unwanted dose is created in kidney. As a result, exact calculation of prescribed radiopharmaceuticals amount is important. Monte Carlo method is used for simulation of radiation transport in body due to random nature of radiation. In this research, for the first time...

متن کامل

Assessment the Effect of Kidney Internal Structure on Gamma Absorbed Dose of Radiopharmaceutical 111In-DTPA

Large quantities of radiopharmaceuticals prescribed for treatment and diagnosis are excreted through kidney. Therefore, radiation unwanted dose is created in kidney. As a result, exact calculation of prescribed radiopharmaceuticals amount is important. Monte Carlo method is used for simulation of radiation transport in body due to random nature of radiation. In this research, for the first time...

متن کامل

MIRD dose estimate report No. 20: radiation absorbed-dose estimates for 111In- and 90Y-ibritumomab tiuxetan.

UNLABELLED Absorbed-dose calculations provide a scientific basis for evaluating the biologic effects associated with administered radiopharmaceuticals. In cancer therapy, radiation dosimetry supports treatment planning, dose-response analyses, predictions of therapy effectiveness, and completeness of patient medical records. In this study, we evaluated the organ radiation absorbed doses from in...

متن کامل

Evaluation of Radiation Exposure Pattern and Radiation Absorbed Dose Resulting from Occupational Exposure of Anesthesiologists to Ionizing Radiation

Introduction: Little information is available concerning the radiation exposure of anesthesiologists, and no such data have previously been collected in Iran. This prospective study was performed to determine the amount of radiation exposure of anesthesiologists for the purpose of assessing whether or not dangerous levels of radiation exposures were being reached, and to identify factors that c...

متن کامل

assessment the effect of kidney internal structure on gamma absorbed dose of radiopharmaceutical 111in-dtpa

large quantities of radiopharmaceuticals prescribed for treatment and diagnosis are excreted through kidney. therefore, radiation unwanted dose is created in kidney. as a result, exact calculation of prescribed radiopharmaceuticals amount is important. monte carlo method is used for simulation of radiation transport in body due to random nature of radiation. in this research, for the first time...

متن کامل

Determination of human absorbed dose from [153Sm]-Samarium maltolate based on distribution data in rats

Background: Therapeutic radiopharmaceuticals are designed to deliver high doses of radiation to selected target organs with an aim of minimizing unwanted radiation to surrounding healthy tissue. Due to the potential of targeted radiotherapy to treat a wide range of malignant conditions, [153Sm]-samarium maltolate was developed for possible therapeutic applications. Materials and Methods: The or...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  350- 350

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com