Dosimetric comparison of TomoDirect and TomoHelical plans in post-mastectomy chest wall radiation therapy

نویسندگان

  • F. Teke Dicle University, Medical School, Department of Radiation Oncology, Yenişehir 21280 Diyarbakır, Turkey
  • H.M. Doğan Dicle University, Medical School, Department of Radiation Oncology, Yenişehir 21280 Diyarbakır, Turkey
  • M. Gümüş Dicle University, Medical School, Department of Radiation Oncology, Yenişehir 21280 Diyarbakır, Turkey
  • M.A. Kaya Dicle University, Medical School, Department of Radiation Oncology, Yenişehir 21280 Diyarbakır, Turkey
چکیده مقاله:

Background: The purpose of this study was to evaluate the characteristics of TomoDirect (TD) plans compared to conventional TomoHelical (TH) plans in chest wall irradiation in patients with breast cancer. Materials and Methods: TD and TH plans for only chest wall were retrospectively created for 30 patients previously treated with TH technique in our clinic. The beam angles were arranged to cover PTV chest wall and to minimize doses to OARs, ipsilateral lung and contralateral breast in TD plan. The prescribed dose was 50 Gy in 25 fractions. Results: The mean treatment times were similar in TH and TD (310.8 and 309 s, respectively, p> 0.05). There was no difference between the values of CI and HI of both plans (p>0.05). The values of Dmean, V5 and V20 of the ipsilateral lung in TD plan was significantly lower than that in TH plan for all 30 patients (p<0.001, p<0.001 and p=0.001, respectively).&nbsp; V25 and V30 values of the heart were significantly lower in TH than those in TD plan in left-sided chest wall irradiation (p=0.006 and p<0.001, respectively). However, V5 values in TH was significantly higher than those in TD (p<0.001). In the right-sided, there was no difference between two plans for V25 and V30 values of heart (p>0.05). Conclusion: Both of TH and TD plans produce acceptable target dose coverage in chest wall RT. Considering the risk of low-dose radiation to the critical organs; TD mode improve dose distribution. &nbsp; &nbsp;

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intensity-modulated radiation therapy using static ports of tomotherapy (TomoDirect): comparison with the TomoHelical mode

PURPOSE With the new mode of Tomotherapy, irradiation can be delivered using static ports of the TomoDirect mode. The purpose of this study was to evaluate the characteristics of TomoDirect plans compared to conventional TomoHelical plans. METHODS TomoDirect and TomoHelical plans were compared in 46 patients with a prostate, thoracic wall or lung tumor. The mean target dose was used as the pr...

متن کامل

A woman post mastectomy and radiation therapy with chest pain.

HISTORY This was the third UCLA hospital admission for this 66-year-old female. Twenty-seven years ago the patient had breast cancer and underwent a left radical mastectomy without chemotherapy, and/or totalbody bone scanning. She then had recurrence in the left supraclavicular fossa involving the lymph nodes and the brachial plexus. She was treated with telecobalt beam over a single anterior d...

متن کامل

Analysis of Hip Joint Dose in Prostate Cancer Radiation Therapy: A Dosimetric Comparison of Treatment Plans

Background and purpose: Radiation therapy as a part of cancer treatment is used in almost 50-60% of involved cases. In prostate cancer radiation therapy, a large volume of pelvis is irradiated, so, it is necessary to preserve sensitive organs around the treatment area, especially rectum and bladder. In this study, some dosimetric parameters such as minimum dose (Dmin), maximum dose (Dmax), mean...

متن کامل

Dosimetric comparison for volumetric modulated arc therapy and intensity-modulated radiotherapy on the left-sided chest wall and internal mammary nodes irradiation in treating post-mastectomy breast cancer

BACKGROUND The aim of the study was to evaluate the dosimetric benefit of applying volumetric modulated arc therapy (VMAT) on the post-mastectomy left-sided breast cancer patients, with the involvement of internal mammary nodes (IMN). PATIENTS AND METHODS The prescription dose was 50 Gy delivered in 25 fractions, and the clinical target volume included the left chest wall (CW) and IMN. VMAT p...

متن کامل

Field-In-Field Plan Versus Tangential Wedged Beam Plan in Chest Wall Radiotherapy of Post-Mastectomy Patients: Treatment Planning Study

Introduction: In this study, dose distribution of the chest wall in post-mastectomy breast cancer patients was evaluated and compared in the tangential wedged beam (TWB) and field-in-field (FIF) plans. Materials and Methods: Thirty-six patients with left-sided breast cancer were enrolled in this study. The FIF and TWB plans were generated for each patient to compare dosimetric parameters of th...

متن کامل

Socioeconomic and racial disparities in the selection of chest wall boost radiation therapy in californian women after mastectomy.

UNLABELLED To better elucidate the socioeconomic and racial differences in women who received postmastectomy radiation therapy with or without a chest wall boost, the records from 4747 women included in the California Cancer Registry were reviewed. Poor and Hispanic women were more likely to receive a chest wall boost than were more affluent and non-Hispanic women. INTRODUCTION Healthcare dis...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره None

صفحات  259- 266

تاریخ انتشار 2017-07

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.