Evaluation of Accuracy and Quality assurance of external beam therapy with photons

نویسندگان

  • Shahram Monadi Radiotherapy Section, Seyed Alshohada Hospital, Isfahan University of Medical Sciences, Isfahan, Iran.
  • Vida rezaee Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan Iran
چکیده مقاله:

Introduction: Receiving exact dose by the patients is vital in radiotherapy. In radiation therapy, the dosimetry of radiations is too important because of successful radiation inquires for delivering the exact dose to the target volume. This study is to evaluate the tolerances and the accuracy of calculated dose of photon beams in the treatment software system. The TECDOC1583 protocol is used to achieve this goal.   Materials and Methods: In this work, the Treatment Planning System TiGRT to distribute dose of photon beams was used and the measurements results in inhomogeneity phantom are compared in 4 levels. Results: According to the TECDOC1583 protocl, the results are accepted but at third and fifth levels the error percent of lung and soft tissue were found to be 4.3%with a 0.3% difference and to be 5/7 with a 3% difference. Conclusion: Because of the low density of electrons in the lung tissues, there were more errors in the planning system hence, the treatment planning needs more accuracy and the data should be reevaluated. Restarting the device and checking the dose values are recommended for applying the algorithms to get more successful treatment. We must be to solve the mistakes because it will effect so undesirable on the treatment.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quality Assurance of External Beam Radiotherapy

'Quality assurance' is all those planned and systematic actions necessary to provide adequate confidence that a product or service will satisfy the given requirements for quality (ISO 9000:1994). As such it is wide ranging, covering all relevant procedures, activities and actions, and hence all groups of staff involved in the process under consideration. 12.1.1.2. Quality assurance in radiother...

متن کامل

Characterization and evaluation of an integrated quality monitoring system for online quality assurance of external beam radiation therapy

PURPOSE The aim of this work was to comprehensively evaluate a new large field ion chamber transmission detector, Integral Quality Monitor (IQM), for online external photon beam verification and quality assurance. The device is designed to be mounted on the linac accessory tray to measure and verify photon energy, field shape, gantry position, and fluence before and during patient treatment. ...

متن کامل

the evaluation of language related engagment and task related engagment with the purpose of investigating the effect of metatalk and task typology

abstract while task-based instruction is considered as the most effective way to learn a language in the related literature, it is oversimplified on various grounds. different variables may affect how students are engaged with not only the language but also with the task itself. the present study was conducted to investigate language and task related engagement on the basis of the task typolog...

15 صفحه اول

effect of seed priming and irrigation regimes on yield,yield components and quality of safflowers cultivars

این مطالعه در سال 1386-87 در آزمایشگاه و مزرعه پژوهشی دانشگاه صنعتی اصفهان به منظور تعیین مناسب ترین تیمار بذری و ارزیابی اثر پرایمینگ بر روی سه رقم گلرنگ تحت سه رژیم آبیاری انجام گرفت. برخی از مطالعات اثرات سودمند پرایمینگ بذر را بر روی گیاهان مختلف بررسی کرده اند اما در حال حاضر اطلاعات کمی در مورد خصوصیات مربوط به جوانه زنی، مراحل نموی، عملکرد و خصوصیات کمی و کیفی بذور تیمار شده ژنوتیپ های م...

Quality Assurance of Beam Accuracy for Leksell Gamma Unit

For the acceptance test and annual quality assurance of the Leksell Gamma Unit, measurement of the beam accuracy, defined as a distance between mechanical and radiological isocenters, poses a challenge to medical physicists. The specification for the beam accuracy is within 0.5 mm for the 4-mm collimator helmet. In this report, we introduce a simple technique to analyze the beam accuracy by usi...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  162- 162

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023