Evaluation of CorePlanTM treatment planning system for 6 and 15 MV photon irradiation

نویسندگان

  • Danial Seifi Makrani Department of Biochemistry and Biophysics, Faculty of Medicine, Mazandaran University of Medical Sciences, Sari, Iran.
  • Tayyeb Pourfallah Department of Biochemistry and Biophysics, Faculty of Medicine, Mazandaran University of Medical Sciences, Sari, Iran.
چکیده مقاله:

Introduction: Radiotherapy is an effective modality to treat esophageal carcinoma. Due to various inhomogenous tissues with a variety of physical and radiological properties which can cause uncertainty in accurate dose calculations in radiation therapy, accuracy of TPS is very important. The aim of this study was to quantify dose calculation accuracy of CoreplanTM TPS in an inhomogenous home-made phantom.   Materials and Methods: Thermoluminescent dosimeter-100 (TLD-100) chips were used within inhomogeneous home-made phantom for dose measurement; CoreplanTM was also applied for dose calculation. Finally, difference between measured doses and calculated doses was gotten to calculate dosimetry accuracy of the TPS at PTV and neighbor’s organ at risks region.   Results: Findings indicated that for regions near PTV, Coreplan TPS leads to an overdose estimation up to 2.3% and 4.8% for the 6 and 15 MV energies, respectively and in regions far from primary field, the Coreplan TPS underestimated the dose compared to the measurements which might be due to scattered radiation that is not well considered in the TPS.   Conclusion: Due to the inhomogeneous in the thorax region, the dose calculation accuracy of TPS should be appropriate. The agreement criterion was determined according to ICRU recommendation, which suggest the accuracy of ±5% in the delivery of an absorbed dose to a target volume. According to the results, it is concluded that the accuracy of dose calculation of Coreplan TPS showed good agreement with experimental data.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

comparison of lead and cerrobend blocks for incident photon flux of 6 and 15 mv x-rays

background: during radiotherapy treatment, critical organs are shielded using lead and cerrobend blocks. the objective of this study is to compare the effects of lead and cerrobend shielding blocks on incident photon beam. methods: collimator scatter factors were measured for open square fields (3 x 3 cm to 40 x 40 cm) defined by collimator jaws and for fields blocked down to smaller asymmetric...

متن کامل

Monte Carlo Simulation of Siemens Primus plus Linac for 6 and 18 MV Photon Beams

Objective: The aim of the present study is to simulate 6 MV and 18 MV photon beam energies of a Siemens Primus Plus medical linear accelerator (Linac) and to verify the simulation by comparing the results with the measured data.Methods: The main components of the head of Siemens Primus Plus linac were simulated using MCNPX Monte Carlo (MC) code. To verify the results, experimental data of perce...

متن کامل

Comparison of pencil beam and collapsed cone algorithms, in radiotherapy treatment planning for 6 and 10 MV photon.

BACKGROUND In radiotherapy treatment, the calculation of radiation dose distribution in target volume lead to an optimum set of planning parameters. This worked has been aimed to compare two photon beam dose calculation algorithms in the Oncentra Treatment Planning system for Varian Linear Accelerator, to assure the quality of treatment planning. METHODS Monitor Units to be delivered on norma...

متن کامل

Determination of room entry times for radiation therapists after routine 15 MV photon treatments

Background: Radiation therapy  uses high-energy radiation to kill cancer cells. Photoneutron contamination and induced radioactivity of high energy therapeutic photon beams are considered as the main source of occupational exposure to radiation therapists who works with linear accelerators operating above 10 MV. Materials and Methods: The gamma dose rates were measured after termination of...

متن کامل

Linear array measurements of enhanced dynamic wedge and treatment planning system (TPS) calculation for 15 MV photon beam and comparison with electronic portal imaging device (EPID) measurements

INTRODUCTION Enhanced dynamic wedges (EDW) are known to increase drastically the radiation therapy treatment efficiency. This paper has the aim to compare linear array measurements of EDW with the calculations of treatment planning system (TPS) and the electronic portal imaging device (EPID) for 15 MV photon energy. MATERIALS AND METHODS The range of different field sizes and wedge angles (fo...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  343- 343

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023