Evaluation of MRI-based Polymer Gel Dosimetry for Measurement of CT Dose Index (CTDI) on 64 slices CT Scanners

نویسندگان

  • Ahmad Farahani B.Sc. in Radiology, Center of Medical Imaging, Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran
  • Behrooz Reafie M.Sc. in Medical Physics, Center of Medical Imaging, Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran
  • Hassan Hashemi Assistant Professor, Radiology Dept., Center of Medical Imaging, Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran
  • Leaila Karimi-Afshar M.Sc. in Medical Physics, Biomedical Engineering, Biomedical Systems & Medical Physics Dept., Tehran University of Medical Sciences, Tehran, Iran
  • Mahmoud Allahverdi Associate Professor, Biomedical Engineering, Biomedical Systems & Medical Physics Dept., Tehran University of Medical Sciences, Tehran, Iran
  • Mohammadreza Ay Assistant Professor, Biomedical Engineering, Biomedical Systems & Medical Physics Dept., Tehran University of Medical Sciences & Research Center for Science and Technology in Medicine, Tehran, Iran.
  • Morteza Bakhteiari M.Sc. in Medical Physics, Biomedical Engineering, Biomedical Systems & Medical Physics Dept., Tehran University of Medical Sciences, Tehran, Iran
  • Nader Riahi Alam Associate Professor, Biomedical Engineering, Biomedical Systems & Medical Physics Dept., Tehran University of Medical Sciences, Tehran, Iran
  • Tayeb Alahverdi purfallah Assistant Professor, Biophysics & Biochemistry Dept., Mazandaran University of Medical Sciences, Mazandaran, Iran
چکیده مقاله:

Introduction: Computed tomography (CT) has numerous applications in clinical procedures but its main problem is its high radiation dose to the patients compared to other imaging modalities using x-ray. CT delivers approximately high doses to the nearby tissues due to the scattering effect, fan beam (beam divergence) and limited collimator efficiency. The radiation dose from multi-slice scanners is greater than the single-slice scanners and since multi-slice scanners increasingly employ a wide beam, 100 mm ion chambers currently used in measuring the CTDI100, are not capable of accurately measuring the total dose profile of the slice width. Therefore, the CT dose is underestimated by using them. The purpose of this study is to measure the Computed Tomography Dose Index (CTDI) of a GE multi-slice CT scanner (64-slice) using polymer gel dosimetry based on MRI imaging (MRPD). CTDI is the sum of point doses along the central axis and estimates the average patient dose during CT scanning. Materials and Methods: For measuring CTDI, after designing and fabricating the phantom and preparing the MAGIC gel, MRI imaging using a 1.5 T Siemens MRI scanner was performed with the imaging parameters of ST = 2 mm, NEX = 1, TE = 20-640 ms and TR = 2000 ms. CTDI was measured with a 100 mm ion chamber (CTDI100) and also the MAGIC gel with MRPD method for 10 mm and 40 mm CT scan nominal widths. Results: Following the measurement of the CTDI100 for 10 mm and 40 mm nominal slice widths of the multi-slice scanner using both ion chamber and MAGIC gel, the results showed that the ion chamber underestimates CTDI100 by 28.71% and 14.03% compared to gel for 10 mm and 40 mm respectively. Discussion and Conclusion: It was concluded from this study that gel dosimeters have the capability to measure CTDI in wide beams of multi-slice CT scanners whereas 100 mm standard ion chamber due to its limited length is not reliable even for a 10 mm beam width. In addition, due to the 3 dimensional nature of gel dosimetry, by using a MAGIC polymer gel, it is possible to obtain a lot of important information from the mentioned profiles such as the actual slice thickness and z-axis geometric efficiency. In addition to the stated parameters, the percentages of the total and partial homogeneities in the slice plane can be obtained only from gel dosimetry. The results of this study show that MAGIC polymer gel dosimetry based on MRI can be used as a supplementary method to using conventional ion chamber dosimetry especially in measurements for slice widths greater than 2 mm.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Dose Distribution Accuracy in HDR Brachytherapy of Esophagus Cancer Based on MRI Normoxic Polymer Gel Dosimetry

Introduction: The purpose of this work was to study the ability of MRI normoxic polymer gel dosimetry for evaluating the dose distribution in HDR brachytherapy of esophagial cancer at Imam Reza brachytherapy center (Mashhad, Iran). Materials and Methods: Initially, 2liters of normoxic gel (MAGIC) was fabricated and then poured into 12 calibration test tubes and placed in a perspex walled phanto...

متن کامل

Calculation of the Scattered Radiation Profile in 64 Slice CT Scanners Using Experimental Measurement

Introduction: One of the most important parameters in x-ray CT imaging is the noise induced by detected scattered radiation. The detected scattered radiation is completely dependent on the scanner geometry as well as size, shape and material of the scanned object. The magnitude and spatial distribution of the scattered radiation in x-ray CT should be quantified for development of robust scatter...

متن کامل

Design and manufacturing a CTDI pediatric phantom for CT dosimetry using TLD, ion chambers, and gel dosimetry

Introduction: Nowadays, the demand for CT-scan is increased, and this issue has become a critical subject in radiation protection, because of the risk of cancer especially for children. The quality assurance of CT images is a necessary factor that can effect on children dose. The CT dose index is an important dosimetry index in CT-Scan dosimetry. The purpose of this study is t...

متن کامل

A new look at CT dose measurement: beyond CTDI.

Equations are derived for generating accumulated dose distributions and the dose line integral in a cylindrical dosimetry phantom for a helical CT scan series from the single slice dose profiles using convolution methods. This exposition will better clarify the nature of the dose distribution in helical CT, as well as providing the medical physicist with a better understanding of the physics in...

متن کامل

Uncertainty Analysis in MRI-based Polymer Gel Dosimetry

Background: Polymer gel dosimeters combined with magnetic resonance imaging (MRI) can be used for dose verification of advanced radiation therapy techniques. However, the uncertainty of dose map measured by gel dosimeter should be known. The purpose of this study is to investigate the uncertainty related to calibration curve and MRI protocol for MAGIC (Methacrylic and Ascorbic acid in Gelatin I...

متن کامل

Initial investigation of a novel light-scattering gel phantom for evaluation of optical CT scanners for radiotherapy gel dosimetry.

There is a need for stable gel materials for phantoms used to validate optical computerized tomography (CT) scanners used in conjunction with radiation-induced polymerizing gel dosimeters. Phantoms based on addition of light-absorbing dyes to gelatine to simulate gel dosimeters have been employed. However, to more accurately simulate polymerizing gels one requires phantoms that employ light-sca...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 6  شماره 2

صفحات  59- 70

تاریخ انتشار 2009-06-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023