Experimental and CFD Study of the Tube Configuration Effect on the Shell-Side Thermal Performance in a Shell and Helically Coiled Tube Heat Exchanger

نویسندگان

  • A. Parvareh CFD Research Centre, Department of Chemical Engineering, Razi University, Kermanshah, Iran
  • M. Rahimi CFD Research Centre, Department of Chemical Engineering, Razi University, Kermanshah, Iran
  • R. Beigzadeh CFD Research Centre, Department of Chemical Engineering, Razi University, Kermanshah, Iran
چکیده مقاله:

"> Despite numerous studies of shell and helically coiled tube heat exchangers, a few investigations on the heat transfer and flow characteristic consider the geometrical effects like coil pitch. Moreover, this scarcity is highlighted for the shell side of this type of heat exchangers. This study reports experimental and Computational Fluid Dynamics (CFD) investigations on heat transfer and flow characteristics of a shell and helically coiled tube heat exchanger. The experiments were carried out using a helically coiled tube, which was placed in a cylindrical shell. Hot and cold water were used as the process fluids on the tube and shell side, respectively. The CFD modeling technique was employed to describe the experimental results, fluid flow pattern, and temperature profiles as well as dead zones in the heat exchanger. Quantitative predicted results of CFD modeling show a good agreement with the experimental data for temperature. The effect of the coil pitch on heat transfer rate was numerically studied and it was found that the heat transfer coefficient intensifies with an increase in coil pitch. The average turbulent kinetic energy (k) for the old coil tube and twice coil pitch heat exchanger was computed as 2.9×10-3 and 3.3×10-3 m 2 /s2, respectively. This indicates an increase of about 14% in flow turbulent kinetic energy. Nusselt numbers were compared with those estimated using published correlation and a mean relative error (MRE) of 14.5% was found between the experimental and predicted data. However, a good agreement was obtained in lower shell Reynolds numbers (lower than Re=200).

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental investigation on heat transfer and pressure drop of Al2O3-base oil nanofluid in a helically coiled tube and effect of turbulator on the thermal performance of shell and tube heat exchanger

These days With respect to the high importance of energy concept, limitation of natural resources, regulation of environmental issues, and global warming, heat transfer systemschr(chr('39')39chr('39')) applications get more attention. In the present paper, the experimental effect of Nano-fluid and turbulator on the heat transfer and pressure drop is investigated. AL2O3-SN300 base oil as nanoflu...

متن کامل

Thermal Analysis of Shell-Side Flow of Shell-and-Tube Heat Exchanger Using Experimental and Theoretical Methods

In this paper the thermal behavior of the shell-side flow of a shell-and-tufe heat exchanger has been studied using theoretical and experimental methods. The experimental method Provided the effect of the major parameters of the shell-side flow on thermal energy exchange. In the numerical method, besides the effect of the major paramerers, the effect of different geometric parameters and Re on ...

متن کامل

Investigating Tubes Material Selection on Thermal Stress in Shell Side Inlet Zone of a Vertical Shell and Tube Heat Exchanger

In this study, the effect of the tube material on the thermal stress generated in a vertical shell and tube heat exchanger is investigated. Shell and tube heat exchangers are the most common heat exchangers used in industries. One of the most common failures in these exchangers in the industry is the tube failure at the junction of the tube to tubesheet. When the shell side and the tube side fl...

متن کامل

Effect of baffle oientation on shell tube heat exchanger performance

In this paper, fluid flow and heat transfer in the laboratory (small size) shell tube heat exchanger are analysed by computational fluid dynamic software. In this type of shell tube heat exchanger baffles with different angles of rotation: 00 (horizontal segmental baffle), 150 (from horizontal), 300, 450, 600, 750, 900 (vertical segmental baffle) is used. Effect of baffle orientation on shell t...

متن کامل

An Experimental Study of Nanofluids Operated Shell and Tube Heat Exchanger with Air Bubble Injection

Shell and Tube heat exchangers are the heat exchangers that are most widely used in industries and for other commercial purposes. There are many techniques that have been utilized to enhance the heat transfer performance of the shell and tube heat exchangers. Air bubble injection is one of the promising and inexpensive techniques that can create turbulence in the fluids resulting in to enhancem...

متن کامل

Experimental Study of Heat Transfer Rate in a Shell and Tube Heat Exchanger with Air Bubble Injection (TECHNICAL NOTE)

Shell and tube heat exchangers are widely being used in many of industrial and power engineering applications. Different techniques have been employed in order to enhance the performance of the heat exchanger. Air bubble injection is one method to increase the turbulence of the flowing fluids which in turn enhance the heat transfer performance. Injecting air bubbles is one of the promising tech...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 12  شماره 2

صفحات  13- 25

تاریخ انتشار 2015-04-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023