GC-FID and HPLC-DAD Methods for the Determination of Menadione Sodium Bisulphite Directly and by Converting Menadione Sodium Bisulphite to Menadione in Pharmaceutical Preparation

نویسندگان

چکیده مقاله:

GC-FID and HPLC-DAD were developed for determination of menadione (MN) and menadione sodium bisulphite (MSB). By means of each method, quantitative analysis of MSB in commercial pharmaceutical was performed in both direct analysis of MSB and analysis of MN by converting MSB to MN with sodium carbonate. GC-FID method was carried out on the HP-5 capillary column using nitrogen gas. HPLC-DAD method was achieved on the reversed phase C8 column by using a mobile phase consisting methanol and water. The calibration curves of GC-FID and HPLC-DAD for both analytes were linear in the same concentration range (0.5–20 μg/mL). Both methods were validated in terms of precision, accuracy, recovery and limits of detection (LOD) and quantitation (LOQ). Although LOD values of HPLC-DAD method (0.010 μg/mL for MN and 0.005 μg/mL for MSB) is lower than obtained values with GC-FID method (0.04 μg/mL for MN and 0.06 μg/mL for MSB), both methods gave similar and favorable results in terms of precision and accuracy. The Student's t-test was applied to investigate the significant of the different between the results of MSB determination with direct analysis of MSB and analysis of MN by converting MSB to MN by means of GC-FID and HPLC-DAD method in dosage form.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

GC-FID and HPLC-DAD Methods for the Determination of Menadione Sodium Bisulphite Directly and by Converting Menadione Sodium Bisulphite to Menadione in Pharmaceutical Preparation

was performed in both direct analysis of MSB and analysis of MN by converting MSB to MN with sodium carbonate. GC-FID method was carried out on the HP-5 capillary column GC-FID and HPLC-DAD methods were developed for determination of menadione (MN) and menadione sodium bisulphite (MSB). By means of each method, quantitative analysis of MSB in commercial pharmaceutical using nitrogen gas. HPLC-D...

متن کامل

gc-fid and hplc-dad methods for the determination of menadione sodium bisulphite directly and by converting menadione sodium bisulphite to menadione in pharmaceutical preparation

gc-fid and hplc-dad were developed for determination of menadione (mn) and menadione sodium bisulphite (msb). by means of each method, quantitative analysis of msb in commercial pharmaceutical was performed in both direct analysis of msb and analysis of mn by converting msb to mn with sodium carbonate. gc-fid method was carried out on the hp-5 capillary column using nitrogen gas. hplc-dad metho...

متن کامل

Determination by Converting Menadione Sodium Bisulphite to Menadione in Pharmaceutical Preparation by Two Derivative Spectrophotometric Methods

Firstand second-order derivative spectrophotometric methods for the quantitative determination by converting menadione sodium bisulphite (MSB) to menadione (M ) with sodium carbonate were developed and validated in pharmaceutical preparation. The quantitative determination of MSB was carried out by using wavelengths 350 nm (for first-order; 1D) and 355 nm (for second-order; 2D) with the lineari...

متن کامل

Different characteristics between menadione and menadione sodium bisulfite as redox mediator in yeast cell suspension

Menadione promoted the production of active oxygen species (AOS) in both yeast cell suspension and the crude enzymes from the cells, but menadione sodium bisulfite (MSB) had little effect on the production of AOS in the cell suspension. MSB kept the stable increase in the electron transfer from intact yeast cells to anode compared to menadione, but the electron transfer promoted by MSB was inhi...

متن کامل

Determination of menadione sodium bisulfite in pharmaceutical preparations by flow-injection on-line photochemical spectrofluorometry.

A flow-injection on-line photochemical spectrofluorometry (FI-PF) was developed for the determination of menadione sodium bisulfite (MSB) using acetone and sodium sulfite as sensitizing reagents. An injected sample band carried by a water stream was on-line merged with a mixed NaOH, Na2SO3 and acetone solution in a "T" connector. It was then driven to pass a knotted PTFE photochemical reactor (...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 13  شماره 2

صفحات  353- 364

تاریخ انتشار 2014-06-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023