Impact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography

نویسندگان

  • Homa Hayati Medical Radiation Sciences Research Team, Tabriz University of Medical Sciences, Tabriz, IRAN
چکیده مقاله:

Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a conventional X-ray CT scan machine for different X-ray spectra, including mono-energetic beams and the spectra generated after passing through physical filters, including copper and tin. The MC-scored photon fluence inside simulated detectors was used to reconstruct the axial CT images by MATLAB software. The resultant images were used to derive the dose calibration curve of the gel for different spectra, based on which the highest sensitivity was selected. Results: Among the calculated gel sensitivities for different beam spectra, the highest increase in average sensitivity was obtained as 23% for the 140 kVp spectrum with copper filter and copper+tin filter. However, the sensitivity of mono-energetic beams showed no considerable variation with the increase of energy from 30 to 140 keV. Conclusion: As the findings indicated, the optimization of photon spectra by means of a physical filter could increase the sensitivity of polymer gels in gel dosimetry using CT imaging. 

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy and reproducibility in x-ray computed tomography polymer gel dosimetry

This work assesses the overall reproducibility and accuracy of an x-ray computed tomography (CT) polymer gel dosimetry (PGD) system using a N-isopropylacrylamide (NIPAM) based polymer gel and investigated what effects the use of generic, inter-batch, and intra-batch gel calibration have on dosimetric and spatial accuracy. Overall excellent spatial and dosimetric accuracy was found with this sys...

متن کامل

Polymer gel dosimetry using x-ray computed tomography: a feasibility study.

A new three-dimensional dosimetry technique using x-ray computed tomography (CT) to analyse polymer gels is proposed. The CT imaging is sensitive to radiation-induced density changes that occur within irradiated polyacrylamide gel (PAG). In this preliminary study, a CT imaging protocol is developed to optimize CT images of PAG; the response of PAG CT number to dose (N(CT)-dose response) and the...

متن کامل

the impact of morphological awareness on the vocabulary development of the iranian efl students

this study investigated the impact of explicit instruction of morphemic analysis and synthesis on the vocabulary development of the students. the participants were 90 junior high school students divided into two experimental groups and one control group. morphological awareness techniques (analysis/synthesis) and conventional techniques were used to teach vocabulary in the experimental groups a...

15 صفحه اول

Polymer gel dosimetry on a multislice computed tomography scanner: effect of changing parameters on CTDI.

Polymer gel dosimetry undertaken on a multislice CT scanner provides an alternative method to conventional dosimetry measurements. Polymer gel dosimeters were used to measure CT radiation doses and compared to TLD and ionization chamber measurements in different diameter phantoms. CTDI was investigated for each of these phantoms for a range of mAs (100-400 mAs), tube voltage (100-135 kV) and no...

متن کامل

the impact of skopos on syntactic features of the target text

the present study is an experimental case study which investigates the impacts, if any, of skopos on syntactic features of the target text. two test groups each consisting of 10 ma students translated a set of sentences selected from advertising texts in the operative and informative mode. the resulting target texts were then statistically analyzed in terms of the number of words, phrases, si...

15 صفحه اول

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 16  شماره 1

صفحات  48- 55

تاریخ انتشار 2019-01-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023