Impact of Silicone gel breast prosthesis on photon beam therapy of recurrence carcinoma post mastectomy

نویسندگان

  • Mpho Sithole Department of Physics, Faculty of , Sefako Makgatho Health Sciences University, Pretoria, South Africa
  • Mpumelelo Nyathi Department of Medical Physics Sefako Makgatho Health Sciences University SouthAfrica
  • Ramaesela Letsoalo Department of Medical Physics, Faculty of Medicine, Sefako Makgatho Health Sciences University, Pretoria, South Africa
چکیده مقاله:

AbstractIntroduction Silicone gel breast implants are used for breast reconstruction post mastectomy. In the event of cancer recurrence, the radiation oncologists are forced to irradiate through the prosthesis device. Due to prosthesis higher atomic number dose perturbations occur during treatment. This study determined the influence of silicone gel thickness on the photon beam distribution. Materials and MethodsA Varian linear accelerator, water phantom (dimensions 30 × 30 × 30 cm3), silicone gel breast prosthesis and Omni-Pro Accept software were used in the study. With the gantry positioned at at a source-to-surface distance (SSD) of 100 cm, the collimators were adjusted to a field size of 10 × 10 cm2 and the 6 MeV photon beam was used. Omni-Pro Accept software was used to plot the percentage depth dose curves and the beam profiles. The results obtained with a Monte Carlo Nuclear Particle (MCNP) Code were validated with the measurement data. The beam profile and percentage depth dose curves were also measured for silicone gel thicknesses (4, 6, 8, 10, 12, 14 and 16 cm) and width 16.5 cm aligned 1 cm below the surface of the water.ResultsThe measured and calculated percentage depth dose (PDD) ratio was 0.03. The measured and calculated beam profiles were 0.5% and 0.9% respectively. For the silicone gel prosthesis, the depth dose values at 0.5 cm below the prosthesis were 2.8%.ConclusionDose perturbations below the breast prosthesis are insignificant, breast prosthesis are safe in the event of carcinoma recurrences.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Depth dose enhancement in the presence of silicone gel breast prosthesis

Background: External beam radiation therapy is often administered to patients implanted with silicone gel breast prosthesis. The aim of this study was to investigate the influence of silicone gel breast prosthesis on photon dose distributions. In the event of recurrence, the oncologist may be forced to irradiate through the prosthetic device. To quantify the dose enhancement or reduction below ...

متن کامل

Evaluation of Local Recurrence of Breast Cancer after Mastectomy and Breast Preservation Therapy

Abstract Introduction: Breast cancer is the most common cancer among women. Even though mastectomy is known as a highly effective method to treat breast cancer, the percentage of patients with local recurrence is still high. Objective: To determine the incidence of local recurrence after mastectomy and breast preservation surgery. Materials and Methods: Patients with breast cancer that under...

متن کامل

The Effect of Breast Reconstruction Prosthesis on Photon Dose Distribution in Breast Cancer Radiotherapy

Introduction: Siliconeprosthetic implants are commonlyutilizedfor tissue replacement and breast augmentation after mastectomy. On the other hand, some patients require adjuvant radiotherapy in order to preventlocal-regional recurrence and increment ofthe overall survival. In case of recurrence, the radiation oncologist might have to irradiate the prosthesis.The aim of this study was to evaluate...

متن کامل

Silicone Gel Bleed on Breast Implants

Silicone is a polymer widely used for medical purposes, including breast implants. The aim of this work is to verify the occurrence of silicone gel diffusion through the lining membrane (bleed) of gel breast implants with smooth, textured, and polyurethane foam coated surfaces, sterilized by dry heat and ethylene oxide. The results enable us to conclude that there is significant difference for ...

متن کامل

the impact of training on second language writing assessment: a case of raters’ biasedness

چکیده هدف اول این تحقیق بررسی تأثیر آموزش مصحح بر آموزش گیرندگان براساس پایایی نمره های آنها در پنج بخش شامل محتوا ، سازمان ، لغت ، زبان و مکانیک بود. هدف دوم این بود که بدانیم آیا تفاوتهای بین آموزشی گیرندگان زن و مرد در پایایی نمرات آنها وجود دارد. برای بررسی این موارد ، ما 90 دانشجو در سطح میانه (متوسط) که از طریق تست تعیین سطح شده بودند انتخاب شدند. بعد از آنها خواستیم که درباره دو موضوع ا...

15 صفحه اول

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره 4

صفحات  256- 263

تاریخ انتشار 2018-10-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023